Overview
How to Program a Strata DK40 System
1-14
Strata DK40 Programming Manual Spring 1999
Program Sequence
Detailed data entry instructions are on the top of each record sheet (
).
➤
To use the program sequence on the record sheet
1.
From the programming telephone, enter the programming mode by pressing a series of
buttons. This is the entry sequence for all programs. These buttons are depicted by the
shaded “
(QWHU 3URJ 0RGH
” on every record sheet. (
)
Important!
When the system is first installed Password 3625 must be used for all
initialisation programs. The password allocated in Program 00-1 or 2 should
then be used. The system passwords (levels 1 and 2) always default to 0000.
Entry to Programming mode can always be gained using the Engineer
password 3625 regardless of the settings in Program 00-1 & 2.
2.
Enter the program number. This sequence is unique for every program. The buttons are
white on every record sheet.
3.
Enter the program data. Again, this sequence is unique for every program. The buttons
are white on every record sheet. To make another entry, repeat this step until ready to
exit the current program.
4.
Exit the current program. This sequence never changes, and the buttons are always
shaded. Upon exiting the current program, repeat Step 2 to enter another program, or
continue with Step 5 to exit the programming mode entirely.
-
&
-
&
4
-
5
-
6
63.
3DVVZRUG
+ROG
6SN
-
&
-
&
63.
3DVVZRUG
+ROG
Figure 1-2 Entering Programming Mode
or