Program 37 Ring Transfer (Camp-on) Recall Time
System & Station
Strata DK40 Programming Manual Spring 1999
3-81
Program 37
Ring Transfer (Camp-on) Recall Time
Program Type:
Station
Initialised Default:
Assigns Ring Transfer Recall Time of 32 seconds to all ports
Program 37 Overview
If a busy or ringing station does not answer a call sent to it via ring (blind) call transfer (lines
or [DNs]), the station originating the ring (blind) transfer is recalled after an amount of time
determined with this program. This time (011~999 seconds) is set independently for each
originating station port. Initialised data sets all stations for a 032-second recall time. Ring
Transfer must first be enabled for the system with Program 10-1, LED 07 ON.