Monobloc Outdoor Unit Service Manual
142
13. Replacement of the service PC board
13.1.
Inverter Box Replacement
Tools:
Screwdriver
Steps:
1. Perform the works of (12.1, 12.2 and 12.3)
2. Disconnect all cables of the inverter box in being careful of wire locations
-
TL sensor
-
TS sensor
-
TD sensor
-
TO sensor
-
TE sensor
-
2 fans
-
Four way valve
-
Two way valve
-
HP switch
-
Thermal cut off of compressor
-
PMV’s (one for 17kW and two for 21kW)
-
LP sensor
-
Wires 1 / 2 / 3 connected of NHC board
-
Power L1 / L2 / L3 / Neutral / Earth
-
Power of compressor (directly on the compressor = 3 wires)
3. Remove six screws which maintain the inverter box
4. Remove the inverter box (to remove it, lift up it)
For 5 minutes after the power is turned off, do not disassemble the inverter to prevent an
electric shock
Compressorpower of 21kW
Compressorpower of 17kW
Fans
NHC connections
Powersupply
Other connections
Summary of Contents for Estia RUA-CP1701H
Page 15: ...Monobloc Outdoor Unit Service Manual 14 4 3 ESTIA hot water cylinder ...
Page 18: ...Monobloc Outdoor Unit Service Manual 17 5 1 3 Wiring Diagram Sheet 6 ...
Page 19: ...Monobloc Outdoor Unit Service Manual 18 5 1 4 Wiring Diagram Sheet 7 ...
Page 20: ...Monobloc Outdoor Unit Service Manual 19 5 1 5 Wiring Diagram Sheet 8 ...
Page 29: ...Monobloc Outdoor Unit Service Manual 28 Variable fixed speed hydraulic models ...
Page 70: ...Monobloc Outdoor Unit Service Manual 69 ...
Page 75: ...Monobloc Outdoor Unit Service Manual 74 ...
Page 157: ...Monobloc Outdoor Unit Service Manual 156 16 2 21kW Fixed Speed Variable Speed Pumpless ...
Page 160: ...Monobloc Outdoor Unit Service Manual 159 ...
Page 161: ...Monobloc Outdoor Unit Service Manual 160 ...
Page 162: ......
Page 163: ......
Page 164: ...TOSHIBA CARRIER EUROPE S A S Route de Thil 01120 Montluel France 1402410501R03 ...