Monobloc Outdoor Unit Service Manual
68
21kW Cooling fan control
Temperature
Range
Compressor Speed Range
45 Hz or lower
45 Hz to 60 Hz
60Hz or higher
Min. Fan
Speed
Max. Fan
Speed
Min. Fan
Speed
Max. Fan
Speed
Min. Fan
Speed
Max. Fan
Speed
38
℃≦
TO
W6
WE
W8
WF
WA
WF
29
℃≦
TO
<
38
℃
W5
WD
W7
WF
W9
WF
15
℃≦
TO
<
29
℃
W3
WA
W5
WC
W7
WE
5
℃≦
TO
<
15
℃
W2
W8
W4
WA
W6
WC
0
℃≦
TO
<
5
℃
W1
W6
W3
W8
W4
WA
-4
℃≦
TO
<
0
℃
W1
W5
W2
W7
W3
W8
TO
<
-4
℃
W1
W4
W3
W5
W3
W6
TO sensor error
W1
WE
W3
WF
W3
WF
8.4.7.2. Heating mode
•
Heating operations of the fan are controlled by a TE sensor, TO sensor and the compressor
revolution number. (Control from a minimum W1 to a maximum is performed according to the table
below).
•
Operation is fixed for 3 minutes after start up by a maximum fan tap corresponding to the zones in
the table below. Thereafter fan control is performed using the temperature from the TE sensor.
•
When TE
≥24°
C continue
placed in
the same state as a normal thermostat OFF without an alarm display. The compressor is restarted
after approximately 2 minutes 30 seconds and such interrupted operation does not constitute an
alarm.
Temperature
Range
Compressor Speed Range
20 Hz or lower
20 Hz to 45 Hz
45Hz or higher
Max. Fan
Speed
Max. Fan
Speed
Max. Fan
Speed
10
℃≦
TO
W7
W8
W9
5
℃≦
TO
<
10
℃
W9
WA
WC
-3
℃≦
TO
<
5
℃
WC
WC
WC
-10
℃≦
TO
<
-3
℃
WC
WC
WC
TO
<
-10
℃
WD
WD
WD
TO sensor error
WD
WD
WD
Summary of Contents for Estia RUA-CP1701H
Page 15: ...Monobloc Outdoor Unit Service Manual 14 4 3 ESTIA hot water cylinder ...
Page 18: ...Monobloc Outdoor Unit Service Manual 17 5 1 3 Wiring Diagram Sheet 6 ...
Page 19: ...Monobloc Outdoor Unit Service Manual 18 5 1 4 Wiring Diagram Sheet 7 ...
Page 20: ...Monobloc Outdoor Unit Service Manual 19 5 1 5 Wiring Diagram Sheet 8 ...
Page 29: ...Monobloc Outdoor Unit Service Manual 28 Variable fixed speed hydraulic models ...
Page 70: ...Monobloc Outdoor Unit Service Manual 69 ...
Page 75: ...Monobloc Outdoor Unit Service Manual 74 ...
Page 157: ...Monobloc Outdoor Unit Service Manual 156 16 2 21kW Fixed Speed Variable Speed Pumpless ...
Page 160: ...Monobloc Outdoor Unit Service Manual 159 ...
Page 161: ...Monobloc Outdoor Unit Service Manual 160 ...
Page 162: ......
Page 163: ......
Page 164: ...TOSHIBA CARRIER EUROPE S A S Route de Thil 01120 Montluel France 1402410501R03 ...