8.4.4. Coil Heating Control
•
This control has the function of heating the compressor by applying a current to the compressor
when not operating instead using a case heater. This control is for the purpose of preventing
stagnation of the refrigerant inside the compressor.
•
Malfunction in the compressor may result if a current is not applied for a specified time before a
test run after installation as was previously the case. Similarly, starting operation after turning the
power OFF and not operating for a long time also requires application of a current before starting
operation, in the same manner as the test run.
•
Application of current is determined by TD and TO sensors. When the TO sensor is defective, a
backup control is automatically performed by the TE sensor. When TO sensor is defective, make a
determination using the LED display of the outdoor interface board.
•
The power is turned off when TD is 30°C or more
.
8.4.4.1. Coil Heating 17kW Unit
L
30W
M
40W
8.4.4.2. Coil Heating 21kW Unit
Intermittent current
100W *
Continous current
100W *
* Total power consumption of inverter and compressor
⚠
While heating the coil, the power sound may be heard. However it is not a trouble.
Summary of Contents for Estia RUA-CP1701H
Page 15: ...Monobloc Outdoor Unit Service Manual 14 4 3 ESTIA hot water cylinder ...
Page 18: ...Monobloc Outdoor Unit Service Manual 17 5 1 3 Wiring Diagram Sheet 6 ...
Page 19: ...Monobloc Outdoor Unit Service Manual 18 5 1 4 Wiring Diagram Sheet 7 ...
Page 20: ...Monobloc Outdoor Unit Service Manual 19 5 1 5 Wiring Diagram Sheet 8 ...
Page 29: ...Monobloc Outdoor Unit Service Manual 28 Variable fixed speed hydraulic models ...
Page 70: ...Monobloc Outdoor Unit Service Manual 69 ...
Page 75: ...Monobloc Outdoor Unit Service Manual 74 ...
Page 157: ...Monobloc Outdoor Unit Service Manual 156 16 2 21kW Fixed Speed Variable Speed Pumpless ...
Page 160: ...Monobloc Outdoor Unit Service Manual 159 ...
Page 161: ...Monobloc Outdoor Unit Service Manual 160 ...
Page 162: ......
Page 163: ......
Page 164: ...TOSHIBA CARRIER EUROPE S A S Route de Thil 01120 Montluel France 1402410501R03 ...