e-STUDIO5540C/6540C/6550C
05/08
Mode
Element
Sub Element
Item
Subitem
Code
Sub-
Code
Details
Default
value
Acceptable
value
RAM
Contents
Proc
edure
ServiceUI
08
K
Displays the number of drum surface potential
sensor control abnormalities.
Setting
mode
Process
Image quality
control
Number of drum
surface potential
sensor control
abnormalities
Counter setting
2560
3
0
0~3
4
M
08
Drum surface potential
sensor control setting
Sets whether drum surface potential sensor control
is enabled or disabled.
0: Disabled
1: Enabled (Performed on Y/M/C/K station)
2: Enabled (Performed on K station)
<Default value>
e-STUDIO5540C/6540C: 0
e-STUDIO6550C: 2
Setting
mode
Process
Image quality
control
2561
Refer to
contents
0~2
1
M
08
Y
Displays the number of drum surface potential
sensor shutter closing control abnormalities.
Setting
mode
Process
Image quality
control
Number of drum
surface potential
sensor control
abnormalities
Counter setting
2577
0
0
0~2
4
M
08
M
Displays the number of drum surface potential
sensor shutter closing control abnormalities.
Setting
mode
Process
Image quality
control
Number of drum
surface potential
sensor control
abnormalities
Counter setting
2577
1
0
0~2
4
M
08
C
Displays the number of drum surface potential
sensor shutter closing control abnormalities.
Setting
mode
Process
Image quality
control
Number of drum
surface potential
sensor control
abnormalities
Counter setting
2577
2
0
0~2
4
M
08
K
Displays the number of drum surface potential
sensor shutter closing control abnormalities.
Setting
mode
Process
Image quality
control
Number of drum
surface potential
sensor control
abnormalities
Counter setting
2577
3
0
0~2
4
M
08
Pattern formation for image
quality TRC control,
Valid/Invalid
Sets whether to perform TRC control correction.0:
Disabled 1: Enabled
Setting
mode
Process
Image quality
control
2600
1
0~1
1
M
08
Development Developer
material replacement display
0: Displayed1: Not displayed
Setting
mode
Process
Developer
2670
0
0~1
1
M
08
Y
Sets the threshold for displaying the replacement
timing (degree of degeneration) of developer
material. When the message appears even if no
defective image is printed, increase the threshold
for approx. 10.
Setting
mode
Process
Developer
Threshold for
displaying
replacement
timing of
developer
material
2675
0
100
50~150
4
M
08
M
Sets the threshold for displaying the replacement
timing (degree of degeneration) of developer
material. When the message appears even if no
defective image is printed, increase the threshold
for approx. 10.
Setting
mode
Process
Developer
Threshold for
displaying
replacement
timing of
developer
material
2675
1
100
50~150
4
M
22
Ver11
08 Setting Mode