A
-
-
-
B
Original exit/reverse sensor
Paper present
No paper
C
Original reverse unit opening/closing
sensor
Cover opened
Cover closed
D
Original reading end sensor
Paper present
No paper
E
-
-
-
F
RADF connection
Connected
Not connected
G
Platen sensor
RADF opened
RADF closed
H
Carriage home position sensor
Home position
Other than home
position
A
-
-
-
B
-
-
-
C
-
-
-
D
APS sensor (APS-R) (APS-5)
Original present
No original
E
APS sensor (APS-C) (APS-4)
Original present
No original
F
APS sensor (APS-3)
Original present
No original
G
APS sensor (APS-2)
Original present
No original
H
APS sensor (APS-1)
Original present
No original
A
Original tray sensor
ON
OFF
B
Original empty sensor
Original present
No original
Original jam access cover opening/
closing sensor
D
RADF open/close sensor
RADF opened
RADF closed
E
Original exit sensor
Original present
No original
F
Original intermediate transport sensor
Original present
No original
G
Original reading start sensor
Original present
No original
H
Original registration sensor
Original present
No original
Original tray width sensor (TWID0S)
(Refer to table 5)
Original tray width sensor (TWID1S)
(Refer to table 5)
Original tray width sensor (TWID2S)
(Refer to table 5)
D
-
-
-
E
-
-
-
F
Original width sensor 1
Original present
No original
G
Original width sensor 2
Original present
No original
H
Original width sensor 3
Original present
No original
A
Sub-hopper toner sensor-M
Normal
Empty
B
-
-
-
C
M Needle electrode cleaner home
position detection
Home position
Other than home
D
Sub-hopper toner sensor-Y
Normal
Empty
E
-
-
-
F
Y needle electrode cleaner home
position detection
Home position
Other than home
G
Sub-hopper connection detection
All sub-hoppers
connected
More than one sub-
hopper disconnected
H
-
-
-
A
Drawer installation detection (EPU tray
installation detection)
Connected
Disconnected
B
Auger lock detection sensor
Rotating
Locked or stopped
C
Sub-hopper toner sensor-K
Normal
Empty
D
-
-
-
E
K needle electrode cleaner home
position detection
Home position
Other than home
F
Sub-hopper toner sensor-C
Normal
Empty
G
-
-
-
H
C needle electrode cleaner home
position detection
Home position
Other than home
[9]
[0]
Cover opened
Cover closed
[8]
A
OFF (H)
ON (L)
B
OFF (H)
ON (L)
C
[5]
[6]
[7]
C
OFF (H)
ON (L)