FIRMWARE UPDATING
11 - 28
(9) “Update Completed.” is displayed at the bottom of the LCD screen after the updating is
completed properly. Turn the power OFF by pressing the [ON/OFF] button.
Notes:
“Update Failed.” is displayed at the bottom of the LCD screen when the updating is not
completed properly. “Failed” appears next to the failed item on the status display. In this case,
shut down the equipment and check the following items. Then clear the problems and restart
updating from the beginning.
- Is the download jig connected properly?
- Is the updating data written to the download jig properly?
- Do the download jig and the equipment operate properly?
(10) Turn the power OFF using the main power switch on the right-hand surface of the equipment,
remove the download jig, and then install the cover plate.
(11) Turn the power ON using the main power switch while holding down the [3] and [C] keys
simultaneously.
(12) Press the [5] key to select “5. Key Backup Restore”, then press the [START] button.
(13) Restore the key and license data by following the steps below.
• Restore the key data by pressing the [1] key to select “1. Key SRAM to FROM”, then press
the [START] button.
• If the state of “FROM Licence Status” is “KeyMismatch”, restore the license data by pressing
the [3] key to select “3. License SRAM to FROM”, then press the [START] button.
• If ADI-HDD is installed, restore the encryption key data by pressing the [5] key to select “5.
ADIKey SRAM to FROM”, then press the [START] button.
(14) Press the [ON/OFF] button to shut down the equipment.
(15) Perform the initialization of the updating data.
• Turn the power ON using the main power switch while pressing the [0] and [8] buttons
simultaneously.
• Key in “9030”, and then press the [START] button.
• Press the [INITIALIZE] button.
[B] Confirmation of the updated data
After the updating is completed, check each data version in the Setting Mode (08) to confirm that the
data were overwritten properly.