e-STUDIO5540C/6540C/6550C
05/08
Mode
Element
Sub Element
Item
Subitem
Code
Sub-
Code
Details
Default
value
Acceptable
value
RAM
Contents
Proc
edure
ServiceUI
08
C
0: -25 1: -20 2: -15 3: -10 4: -5 5: ±0 6: +5 7:
+10 8: +15 9: +20 10: +25 (Unit: μW)
Setting
mode
Process
Image quality
control
Laser power
offset correction
setting (Normal
speed)
2525
2
5
0~10
4
M
08
K
0: -25 1: -20 2: -15 3: -10 4: -5 5: ±0 6: +5 7:
+10 8: +15 9: +20 10: +25 (Unit: μW)
Setting
mode
Process
Image quality
control
Laser power
offset correction
setting (Normal
speed)
2525
3
5
0~10
4
M
08
Y
0: -25 1: -20 2: -15 3: -10 4: -5 5: ±0 6: +5 7:
+10 8: +15 9: +20 10: +25 (Unit: μW)
Setting
mode
Process
Image quality
control
Laser power
offset correction
setting
(Decelerating 1)
2526
0
5
0~10
4
M
08
M
0: -25 1: -20 2: -15 3: -10 4: -5 5: ±0 6: +5 7:
+10 8: +15 9: +20 10: +25 (Unit: μW)
Setting
mode
Process
Image quality
control
Laser power
offset correction
setting
(Decelerating 1)
2526
1
5
0~10
4
M
08
C
0: -25 1: -20 2: -15 3: -10 4: -5 5: ±0 6: +5 7:
+10 8: +15 9: +20 10: +25 (Unit: μW)
Setting
mode
Process
Image quality
control
Laser power
offset correction
setting
(Decelerating 1)
2526
2
5
0~10
4
M
08
K
0: -25 1: -20 2: -15 3: -10 4: -5 5: ±0 6: +5 7:
+10 8: +15 9: +20 10: +25 (Unit: μW)
Setting
mode
Process
Image quality
control
Laser power
offset correction
setting
(Decelerating 1)
2526
3
5
0~10
4
M
08
Laser power offset
correction setting (High
speed)
0: -25 1: -20 2: -15 3: -10 4: -5 5: ±0 6: +5 7:
+10 8: +15 9: +20 10: +25 (Unit: μW)
Setting
mode
Process
Image quality
control
2527
5
0~10
1
M
08
(Y)Display/0 clearing
Counts the abnormality detection of image quality
control.
Accumulating total of [CE10], [CE20] and [CE40]
Setting
mode
Process
Image quality
control
Abnormality
detection
2528
0
0~16
1
Yes
M
08
(M)Display/0 clearing
Counts the abnormality detection of image quality
control.
Accumulating total of [CE10], [CE20] and [CE40]
Setting
mode
Process
Image quality
control
Abnormality
detection
2529
0
0~16
1
Yes
M
08
(C)Display/0 clearing
Counts the abnormality detection of image quality
control.
Accumulating total of [CE10], [CE20] and [CE40]
Setting
mode
Process
Image quality
control
Abnormality
detection
2530
0
0~16
1
Yes
M
08
(K)Display/0 clearing
Counts the abnormality detection of image quality
control.
Accumulating total of [CE10], [CE20] and [CE40]
Setting
mode
Process
Image quality
control
Abnormality
detection
2531
0
0~16
1
Yes
M
08
Y
0: -80 1: -60 2: -40 3: -20 4: -10 5: 0 6: +10 7:
+20 8: +40 9: +60 10: +80 (Unit: V)
Setting
mode
Process
Image quality
control
Contrast voltage
offset correction
setting
(Decelerating 2)
2546
0
5
0~10
4
M
08
M
0: -80 1: -60 2: -40 3: -20 4: -10 5: 0 6: +10 7:
+20 8: +40 9: +60 10: +80 (Unit: V)
Setting
mode
Process
Image quality
control
Contrast voltage
offset correction
setting
(Decelerating 2)
2546
1
5
0~10
4
M
08
C
0: -80 1: -60 2: -40 3: -20 4: -10 5: 0 6: +10 7:
+20 8: +40 9: +60 10: +80 (Unit: V)
Setting
mode
Process
Image quality
control
Contrast voltage
offset correction
setting
(Decelerating 2)
2546
2
5
0~10
4
M
20
Ver11
08 Setting Mode