Table 12. Input Function Target Selections and the Associated Communications Numbers.
Input Setting/Communication
Number
Function
Resolution
/Unit
AM/FM/FP
Input Setting
Comm.
Number
Monitor
Display Input
Setting
Comm.
Number
2000
FD00
3000
FE00
Output Frequency
0.01 Hz
2002
FD02
3002
FE02
Frequency Reference
0.01 Hz
2003
FD03
3003
FE03
Output Current
0.01%
2004
FD04
3004
FE04
DC Bus Voltage
0.01%
2005
FD05
3005
FE05
Output Voltage
0.01%
2015
FD15
3015
FE15
Compensated Frequency
0.01 Hz
2016
FD16
3016
FE16
Speed Feedback (Realtime) (See Note 1)
0.01 Hz
2017
FD17
3017
FE17
Speed Feedback (1 Sec Filter) (See Note 1)
0.01 Hz
2018
FD18
3018
FE18
Torque (See Note 2)
0.01%
2019
FD19
3019
FE19
Torque Command (See Note 2)
0.01%
2020
FD20
3020
FE20
Torque Current (See Note 2)
0.01%
2021
FD21
3021
FE21
Excitation Current
0.01%
2022
FD22
3022
FE22
PID Feedback Value
0.01 Hz
2023
FD23
3023
FE23
Motor Overload Ratio
0.01%
2024
FD24
3024
FE24
ASD Overload Ratio
0.01%
2025
FD25
3025
FE25
DBR Overload Ratio
1%
2028
FD28
3028
FE28
DBR Load Ratio
1%
2029
FD29
3029
FE29
Input Power
0.01 kW
2030
FD30
3030
FE30
Output Power
0.01 kW
3031
FE31
Pattern Operation Group Number
0.1
3032
FE32
Pattern Operation Cycles Remaining
1
3033
FE33
Pattern Operation Preset Speed Number
1
3034
FE34
Pattern Operation Preset Speed Time Remaining
0.1
2050
FD50
Express-Speed Load Torque Monitor 1
0.01%
2051
FD51
Express-Speed Load Torque Monitor 2
0.01%
3035
FE35
RR Input
1%
3036
FE36
V/I Input
1%
3037
FE37
RX Input (See Note 2)
1%
3038
FE38
RX2 Option (AI1) Input (See Note 2)
1%
3039
FE39
RX2 Option (AI1) Input
1%
3040
FE40
FM Output
1
3041
FE41
AM Output
1
Note 1: If no PG feedback is used an estimated speed value is displayed.
Note 2: My Function cannot process negative values — A negative value is processed by My Function as an absolute
value.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]