5-7
Z Master 500 Gas Series Service Manual
5
ENGINE
10. Secure the throttle and choke cables to the bracket
located on the engine valve cover with a tie strap
(Fig. 178).
Fig 178
DSC-2972
11. Install the air cleaner assembly through the air
cleaner assembly bracket and install the air cleaner
end cap (Fig. 179).
Fig 179
DSC-2958
Fig 181
DSC-2957
13. Install the hose to the engine and tighten the hose
clamp (Fig. 181).
Fig 180
DSC-2956
12. Install the bolt, spacer, spring, and nut on the top of
the air cleaner bracket and tighten (Fig. 180).
14. Install the battery negative cable to the battery.
15. Test operate engine; adjust choke and throttle cables
as required. Check engine low and high idle are to
specification.