6-9
Z Master 500 Gas Series Service Manual
6
2. Using a multimeter, follow the procedures listed
below (Fig. 336).
Fig 336
brake switch
The switch is in the safety circuit. If the engine is running
and the operator vacates the seat with either the PTO
engaged or the parking brake off, the engine will shut
down.
Note: With a delay module in the system, there will
be a slight delay before the engine shuts
down after the operator vacates the seat.
Plunger
Not
Depressed
Plunger Depressed
A/B Terminals – Closed
Circuit – Continuity
A/B Terminals – Open
Circuit – No Continuity
C/D Terminals – Open
Circuit – No Continuity
C/D Terminals – Closed
Circuit – Continuity
The seat switch is fastened to the bottom of seat base
on all models equipped with deluxe suspension seats
(Fig. 337).
Fig 337
DSC-2555
SEAT SWITCH
Purpose
Location
ELECTRICAL
A
B
C
D
Summary of Contents for Z Master 500 Series
Page 1: ...Z Master 500 Series Gasoline Engine Models Service Manual LCE Products...
Page 3: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 7: ...iv Z Master 500 Gas Series Service Manual TABLE OF CONTENTS THIS PAGE INTENTIONALLY LEFT BLANK...
Page 115: ...5 44 Z Master 500 Gas Series Service Manual 5 ENGINE THIS PAGE INTENTIONALLY LEFT BLANK...
Page 133: ...6 18 Z Master 500 Gas Series Service Manual 6 Kohler EFI Electric Fuel Injection ELECTRICAL...
Page 136: ...6 21 Z Master 500 Gas Series Service Manual 6 Kawasaki L C Liquid Cooled ELECTRICAL...
Page 137: ...6 22 Z Master 500 Gas Series Service Manual 6 ELECTRICAL THIS PAGE INTENTIONALLY LEFT BLANK...
Page 167: ...Z Master 500 Series Gasoline Engine Models Service Manual Form No 492 9151...