![background image](http://html.mh-extra.com/html/thermo-king/super-ii-sr/super-ii-sr_manual_1104381063.webp)
Engine Maintenance (Rev 6/98)
53
Changing the Antifreeze
1.
Run the engine until it is up to its normal operating
temperature. Stop the unit.
2.
Open the engine block drain and completely drain the
coolant. Observe the coolant color. If the coolant is
dirty, proceed with a, b and c. Otherwise go to 3.
1.
Radiator
4.
Expansion Tank
2.
Radiator Cap
5.
Thermostat Housing
3.
Coolant Level Sensor
6.
Accumulator Tank
AEA1361
1
4
5
6
CAUTION: Avoid direct contact with hot cool-
ant.
a.
Run clear water into the radiator and allow it to
drain out of the block until it is clear.
b.
Close the block drain and install a commercially
available radiator and block flushing agent, and
2
3
Summary of Contents for Super II SR+
Page 4: ......
Page 10: ...ii ...
Page 14: ...4 ...
Page 22: ...Unit Description Rev 6 98 12 Front View AEA1350 ...
Page 23: ...Unit Description Rev 6 98 13 Right Side Door Open AEA1351 ...
Page 24: ...Unit Description Rev 6 98 14 Left Side Doors Open AEA1352 ...
Page 26: ...Operating Instructions Rev 6 98 16 Control Box Cover AEA1354 ...
Page 34: ...24 ...
Page 42: ...Electronic Controls Rev 6 98 32 SOFTWARE REVISION 04XX ALARMS AEA1358 ...
Page 82: ...72 ...
Page 90: ...80 ...
Page 116: ...106 ...
Page 120: ...110 ...
Page 130: ...120 ...
Page 141: ...131 Schematic Diagram SBIII SII RMNII 30 SR MPIV ...
Page 142: ...132 Wiring Diagram SII SBIII RMN30 SR MPIV Page 1 of 4 ...
Page 143: ...133 Wiring Diagram SII SBIII RMN30 SR MPIV Page 2 of 4 ...
Page 144: ...134 Wiring Diagram SII SBIII RMN30 SR MPIV Page 3 of 4 ...
Page 145: ...135 Wiring Diagram SII SBIII RMN30 SR MPIV page 4 of 4 ...