15
Operating Instructions
UNIT CONTROLS
Two sets of controls are used to operate a unit that is
equipped with a THERMOGUARD uP IV+ microprocessor
controller. The switch panel contains the switches that con-
trol the basic operation of the unit. The microprocessor con-
trol panel contains the LCD display and the keypad that
controls the operation of the microprocessor.
Switch Panel
1.
ON-OFF Switch. This switch energizes the unit’s elec-
tric control system.
a.
ON Position. The unit will operate under the con-
trol of the microprocessor.
OFF Position. The electric control system is de-ener-
gized and the unit will not operate.
Switch Panel
1.
PREHEAT-START Switch. This switch is used to man-
ually start the diesel engine. When held in the PRE-
HEAT position, it energizes only the glow plugs to help
start the engine. When held in the START position, it
energizes the starter and the glow plugs. Hold the
switch in the START position until the engine starts to
fire and pick up speed. DO NOT release the switch too
soon when the engine is extremely cold.
2.
MANUAL DEFROST Switch. Pressing this switch
causes the unit to initiate a defrost cycle, if the evapora-
tor coil temperature is below 7° C (45° F). If the evapo-
rator coil temperature is above 7° C (45° F), pressing
this switch will not affect the operation of the unit.
3.
AIR SWITCH. The air switch senses the air pressure
difference between the evaporator coil inlet and outlet.
The switch automatically places the unit on defrost
when ice or frost builds up on the coil to a point where
the air flow across the coil is restricted 40-50 percent.
4.
CYCLE-SENTRY/CONTINUOUS Switch. This
switch selects continuous run operation or CYCLE-
SENTRY operation.
a.
CONTINUOUS Position. The unit must be started
manually with the On-Off and Preheat-Start
switches. After it is started, the unit will operate
continuously until the On-Off switch is turned
OFF.
b.
CYCLE-SENTRY Position. All unit starting oper-
ations are performed automatically on micropro-
cessor demand. Starting functions such as glow
plug preheat, fuel and throttle solenoid control, and
cranking are performed automatically.
1.
On-Off Switch
2.
Preheat-Start Switch
3.
Manual Defrost Switch
4.
CYCLE-SENTRY Continuous
Run Switch
1
2
3
4
AEA1353
Summary of Contents for Super II SR+
Page 4: ......
Page 10: ...ii ...
Page 14: ...4 ...
Page 22: ...Unit Description Rev 6 98 12 Front View AEA1350 ...
Page 23: ...Unit Description Rev 6 98 13 Right Side Door Open AEA1351 ...
Page 24: ...Unit Description Rev 6 98 14 Left Side Doors Open AEA1352 ...
Page 26: ...Operating Instructions Rev 6 98 16 Control Box Cover AEA1354 ...
Page 34: ...24 ...
Page 42: ...Electronic Controls Rev 6 98 32 SOFTWARE REVISION 04XX ALARMS AEA1358 ...
Page 82: ...72 ...
Page 90: ...80 ...
Page 116: ...106 ...
Page 120: ...110 ...
Page 130: ...120 ...
Page 141: ...131 Schematic Diagram SBIII SII RMNII 30 SR MPIV ...
Page 142: ...132 Wiring Diagram SII SBIII RMN30 SR MPIV Page 1 of 4 ...
Page 143: ...133 Wiring Diagram SII SBIII RMN30 SR MPIV Page 2 of 4 ...
Page 144: ...134 Wiring Diagram SII SBIII RMN30 SR MPIV Page 3 of 4 ...
Page 145: ...135 Wiring Diagram SII SBIII RMN30 SR MPIV page 4 of 4 ...