Electronic Controls (Rev 6/98)
34
RUNNING A FULL PRETRIP TEST
NOTE: The unit must be in diesel mode.
1.
Turn the unit On-Off switch ON. Be sure the unit is in
CYCLE-SENTRY mode (the CYCLE-SENTRY icon
will be present).
2.
Clear all alarms using the CODE and CLEAR keys.
3.
When the standard display appears, press and hold the
TK key (the logo key) for at least 3 seconds. The pre-
trip prompt screen PrETRIP will appear in the display.
4.
Press the ENTER key to start a pretrip test. The display
will briefly show [LOAD] and the unit will then begin a
pretrip test. For complete details of the pretrip test, see
T.I.P. Information and Procedures.
NOTE: The ENTER key must be pressed to start the pre-
trip test. If the ENTER key is not pressed, the display will
return to the standard display after about 10 seconds.
NOTE: The pretrip test should not be interrupted unless
absolutely necessary. If the pretrip test must be halted,
turn the On-Off switch OFF. This will generate one or
more alarms, including an alarm code 28 - Pretrip Abort
alarm. This is normal.
DISPLAYING THE SOFTWARE REVISION
Turn the unit On-Off switch to ON.
Press and hold the TK key (logo key) for at least 3 seconds.
The pretrip prompt screen PrETRIP will appear in the dis-
play.
Press the SELECT key as required to display REV and the
software revision number will appear on the display.
OPERATING SERVICE TEST MODE
NOTE: Read and understand the “Service Test Mode
Notes,” and the “Service Test Mode Functions,” section in
this chapter before operating the unit in the service test
mode.
1.
Place the CYCLE-SENTRY-Continuous switch in the
CONTINUOUS position and turn the unit On-Off
switch ON. The unit may be started or left off as
required.
2.
Press and hold the TK key (logo key) until [PrETRIP]
appears in the display.
3.
Press the SELECT key until [REV] appears in the dis-
play.
4.
Press and hold both the TK key (logo key) and the
CLEAR key until [tESt] and [HSC] appears in the dis-
play. The microprocessor is now displaying the service
test mode prompt. See more information in this chapter
concerning available operating modes.
5.
Use the up and down arrow keys to select the desired
operating mode. Press the ENTER key to load the oper-
ating mode. The unit will remain in the selected mode
for 15 minutes or until another mode is selected and
entered.
Summary of Contents for Super II SR+
Page 4: ......
Page 10: ...ii ...
Page 14: ...4 ...
Page 22: ...Unit Description Rev 6 98 12 Front View AEA1350 ...
Page 23: ...Unit Description Rev 6 98 13 Right Side Door Open AEA1351 ...
Page 24: ...Unit Description Rev 6 98 14 Left Side Doors Open AEA1352 ...
Page 26: ...Operating Instructions Rev 6 98 16 Control Box Cover AEA1354 ...
Page 34: ...24 ...
Page 42: ...Electronic Controls Rev 6 98 32 SOFTWARE REVISION 04XX ALARMS AEA1358 ...
Page 82: ...72 ...
Page 90: ...80 ...
Page 116: ...106 ...
Page 120: ...110 ...
Page 130: ...120 ...
Page 141: ...131 Schematic Diagram SBIII SII RMNII 30 SR MPIV ...
Page 142: ...132 Wiring Diagram SII SBIII RMN30 SR MPIV Page 1 of 4 ...
Page 143: ...133 Wiring Diagram SII SBIII RMN30 SR MPIV Page 2 of 4 ...
Page 144: ...134 Wiring Diagram SII SBIII RMN30 SR MPIV Page 3 of 4 ...
Page 145: ...135 Wiring Diagram SII SBIII RMN30 SR MPIV page 4 of 4 ...