Disassembly
1.
Remove the piston end cap (round end).
2.
Remove the cotter pin from the castle nut and remove
the nut.
3.
Remove the spring and piston.
4.
Loosen all the bolts on the bellows end cap.
CAUTION: This end cap is under slight spring
pressure.
5.
Break the gasket free and remove the end cap.
6.
Note the number of shims next to the cap. These can be
reused.
7.
Remove the bellows.
8.
Inspect all the parts.
•
Piston and cap for wear (scuff marks).
•
Body for stripped threads.
1.
Inspect Cap
2.
Inspect Spring
3.
Shims
•
Bellows end cap for damage in the pilot hole.
NOTE: The bellows is normally replaced.
9.
Clean the parts that will be reused.
Reassembly
1.
Install the bellows with the O-ring in the housing.
2.
Center the spring on the bellows shoulder.
1.
Inspect for Wear
1.
Inspect for Damage
Summary of Contents for Super II SR+
Page 4: ......
Page 10: ...ii ...
Page 14: ...4 ...
Page 22: ...Unit Description Rev 6 98 12 Front View AEA1350 ...
Page 23: ...Unit Description Rev 6 98 13 Right Side Door Open AEA1351 ...
Page 24: ...Unit Description Rev 6 98 14 Left Side Doors Open AEA1352 ...
Page 26: ...Operating Instructions Rev 6 98 16 Control Box Cover AEA1354 ...
Page 34: ...24 ...
Page 42: ...Electronic Controls Rev 6 98 32 SOFTWARE REVISION 04XX ALARMS AEA1358 ...
Page 82: ...72 ...
Page 90: ...80 ...
Page 116: ...106 ...
Page 120: ...110 ...
Page 130: ...120 ...
Page 141: ...131 Schematic Diagram SBIII SII RMNII 30 SR MPIV ...
Page 142: ...132 Wiring Diagram SII SBIII RMN30 SR MPIV Page 1 of 4 ...
Page 143: ...133 Wiring Diagram SII SBIII RMN30 SR MPIV Page 2 of 4 ...
Page 144: ...134 Wiring Diagram SII SBIII RMN30 SR MPIV Page 3 of 4 ...
Page 145: ...135 Wiring Diagram SII SBIII RMN30 SR MPIV page 4 of 4 ...