![background image](http://html.mh-extra.com/html/thermo-king/super-ii-sr/super-ii-sr_manual_1104381048.webp)
Electronic Controls (Rev 6/98)
38
Press the up arrow key
again to display
[MB1.0]. Press ENTER
to activate this mode.
The display will show
[tESt] and [MB1.0].
The unit is forced to modulation cool bypass mode—
modulation valve 50% closed.
The run relay is energized.
The cool and modulation icons are ON.
Press the up arrow key
again to display
[MC0.5]. Press ENTER
to activate this mode.
The display will show
[tESt] and [MC0.5]
The unit is forced to modulation cool mode—modulation
valve set for 50% modulation.
The run relay is energized.
The cool and modulation icons are ON.
Press the up arrow key
again to display
[MC1.0]. Press ENTER
to activate this mode.
The display will show
[tESt] and [MC1.0]
The unit is forced to modulation cool mode—modulation
valve set for 100% modulation.
The run relay is energized.
The cool and modulation icons are ON.
Press the up arrow key
again to display
[MH0.5]. Press ENTER
to activate this mode.
The display will show
[tESt] and [MH0.5]
The unit is forced to modulation heat mode—
modulation valve set for 50% modulation.
The run relay and heat output are energized.
The heat and modulation icons are ON.
Press the up arrow key
again to display
[MH1.0]. Press ENTER
to activate this mode.
The display will show
[tESt] and [MH1.0].
The unit is forced to modulation heat mode—
modulation valve set for 100% modulation.
The run relay and heat output are energized.
The heat and modulation icons are ON.
Press the up arrow key
again to display [HSC].
The display will show
[tESt] and [HSC]
The unit is forced to high speed heat mode.
The run relay, heat output and high speed relay are
energized.
The heat and high speed icons are ON.
To exit service test mode
Turn the unit On-Off
switch OFF and back
ON.
The display will return to
the standard display.
The unit will operate normally.
SERVICE TEST MODE FUNCTION TABLE
Summary of Contents for Super II SR+
Page 4: ......
Page 10: ...ii ...
Page 14: ...4 ...
Page 22: ...Unit Description Rev 6 98 12 Front View AEA1350 ...
Page 23: ...Unit Description Rev 6 98 13 Right Side Door Open AEA1351 ...
Page 24: ...Unit Description Rev 6 98 14 Left Side Doors Open AEA1352 ...
Page 26: ...Operating Instructions Rev 6 98 16 Control Box Cover AEA1354 ...
Page 34: ...24 ...
Page 42: ...Electronic Controls Rev 6 98 32 SOFTWARE REVISION 04XX ALARMS AEA1358 ...
Page 82: ...72 ...
Page 90: ...80 ...
Page 116: ...106 ...
Page 120: ...110 ...
Page 130: ...120 ...
Page 141: ...131 Schematic Diagram SBIII SII RMNII 30 SR MPIV ...
Page 142: ...132 Wiring Diagram SII SBIII RMN30 SR MPIV Page 1 of 4 ...
Page 143: ...133 Wiring Diagram SII SBIII RMN30 SR MPIV Page 2 of 4 ...
Page 144: ...134 Wiring Diagram SII SBIII RMN30 SR MPIV Page 3 of 4 ...
Page 145: ...135 Wiring Diagram SII SBIII RMN30 SR MPIV page 4 of 4 ...