68
TK 61555-2-MM-EN
W
WA
AR
RN
NIIN
NG
G
R
Riisskk o
off IIn
njju
urry
y!!
D
Do
o n
no
ott p
pu
utt ffiin
ng
ge
errss b
be
ettw
we
ee
en
n tth
he
e b
be
elltt a
an
nd
d tth
he
e tte
en
nssiio
on
ne
err p
pu
ulllle
ey
y..
2. Slide the belt from the tensioner pulley by hand in the direction shown below.
Figure 44. Remove Belt from Tensioner Pulley
3. Slowly release the downward pressure on the wrench to remove it from the tensioner bolt.
The wrench will rise above the horizontal starting position under the force of the spring.
4. Loosen (or remove) the mounting screws for the upper blower condenser spinning enough to
allow the condenser spinning to be moved away from the upper blower and the belt to be
passed between the upper blower and its condenser spinning.
5. Remove the old belt.
6. Slide the new belt between the upper blower and its condenser spinning and install the new
belt on the pulleys in stages as shown below, and to tighten the mounting screws for the
upper blower condenser spinning.
Figure 45. Stage 1