EMI-3000
•
TK Bluebox
CYCLE-SENTRY
™
™
Start-Stop Controls
The CYCLE-SENTRY Start-Stop fuel saving system provides optimum operating economy.
W
WA
AR
RN
NIIN
NG
G
R
Riisskk o
off IIn
njju
urry
y!!
T
Th
he
e u
un
niitt cca
an
n sstta
arrtt a
att a
an
ny
y ttiim
me
e w
wiitth
ho
ou
utt w
wa
arrn
niin
ng
g.. P
Prre
essss tth
he
e O
OF
FF
F kke
ey
y o
on
n tth
he
e H
HM
MII cco
on
nttrro
oll
p
pa
an
ne
ell a
an
nd
d p
plla
acce
e tth
he
e m
miiccrro
op
prro
occe
esssso
orr O
On
n//O
Offff ssw
wiittcch
h iin
n tth
he
e O
Offff p
po
ossiittiio
on
n b
be
effo
orre
e iin
nssp
pe
eccttiin
ng
g o
orr
sse
errv
viicciin
ng
g a
an
ny
y p
pa
arrtt o
off tth
he
e u
un
niitt..
When CYCLE-SENTRY Mode is selected, the unit will start and stop automatically to maintain
setpoint, keep the engine warm, and the battery charged. When Continuous Mode is selected,
the unit starts automatically and runs continuously to maintain setpoint and provide constant
airflow.
N
No
otte
e:: The SR-3 Controller provides a wide range of control and programming flexibility.
However, pre-programming of the unit controller may prohibit operation in certain
temperature ranges within some modes and may also prohibit certain modes of operation.
In CYCLE-SENTRY, if the block temperature falls below -1 C (30 F), the engine will start and run
until the block temperature is above 32 C (90 F). If the battery voltage falls to the programmed
limit selected by CYCLE-SENTRY Battery Voltage (typically 12.6 volts) and Diesel CYCLE-SENTRY
mode is selected, the engine will start and run until the charge rate falls below that programmed
by CYCLE-SENTRY Amps (typically 2 amperes).
Features of the CYCLE-SENTRY system are:
•
Offers either CYCLE-SENTRY or Continuous Run operation.
•
Controller regulated all season temperature control.
•
Maintains minimum engine temperature in low ambient conditions.
•
Battery Sentry keeps batteries fully charged during unit operation.
•
Variable preheat time.
•
Preheat indicator buzzer.
Data Logging
There are two separate data loggers. The data is downloaded through one of the data ports using
a flash drive or a PC and WinTrac software.
S
Se
errv
viicce
eW
Wa
attcch
h
™
™
:: ServiceWatch is standard equipment. It records operating events, alarm codes,
and compartment temperatures as they occur and at preset intervals. This information is
typically used to analyze unit performance. Use a USB port to download the ServiceWatch data.
IIm
mp
po
orrtta
an
ntt:: A ServiceWatch download can be helpful when diagnosing a problem in a unit with
an SR-3 Controller. Therefore, it is recommended that a ServiceWatch download be
performed to help diagnose a problem. A ServiceWatch download must be
preformed before contacting the Thermo King Service Department for assistance in
diagnosing a problem. Refer to the for information about downloading the
ServiceWatch Data Logger and viewing the data.
C
Ca
arrg
go
oW
Wa
attcch
h
™
™
:: CargoWatch data logging requires the installation of optional sensors. Up to six
temperature sensor/probes and four door switches can be installed. CargoWatch also logs the
setpoint. Use the USB Port to download the CargoWatch data. If optional temperature sensors
are installed, the readings are displayed as Datalogger Sensor (1-6) Temperature in the sensor
readings. See “Using the Sensors Key” in the Operating Instructions Chapter.
A printer can also be used to print a report of the optional sensor readings. See “Data Logger
(CargoWatch)” in the Operating Instructions Chapter.