75
Engine Maintenance
EMI 3000
EMI 3000 is an extended maintenance interval
package that is standard equipment on this unit.
The EMI 3000 package consists of the following
key components:
•
New EMI 3000-Hour Cyclonic Air Cleaner
Assembly and Air Cleaner Element
•
New EMI 3000-Hour Fuel Filter (black with
gold lettering)
•
New EMI 3000-Hour Dual Element Oil Filter
(black with gold lettering)
•
API Rating CG-4 Mineral Oil (ACEA Rating
E2-96 for Europe)
•
Five Year or 12,000 Hour ELC (Extended Life
Coolant).
The EMI package allows standard maintenance
intervals to be extended to 3,000 hours, or 2 years,
whichever occurs first.
NOTE: Units equipped with the EMI 3000
package do require regular inspection in
accordance with Thermo King’s maintenance
recommendations.
NOTE: The new EMI 3000 oil filters and new
EMI 3000 air cleaners are NOT interchangeable
with the oil filters and air cleaners previously
used in trailer units.
Engine Lubrication System
The TK 486 engine has a pressure lubrication
system. Refer to the TK 482 and TK 486 Engine
Overhaul Manual TK 50136 for a detailed
description of the engine lubrication system.
Engine Oil Change
The engine oil should be changed according to the
Maintenance Inspection Schedule. Drain the oil
only when the engine is hot to ensure that all the
oil drains out. When changing oil, keep unit and
trailer level so all the oil can flow from the oil
pan. It is important to get as much of the oil out as
possible because most of the dirt particles are
contained in the last few quarts of oil that drain
out of the pan. Refill the pan with 13 quarts
(12.3 liters) and check the dipstick level. Run the
unit, and then recheck the oil level. The engine oil
level should be at the FULL mark with the
dipstick turned (threaded) into the oil pan. Never
overfill. See the Specifications chapter for the
correct type of oil.
Oil Filter Change
The oil filter should be changed along with the
engine oil. Use a genuine Thermo King extended
maintenance oil filter.
1. Remove the filter.
2. Apply oil to the rubber ring of the new filter
and install the filter.
3. Tighten the filter until the rubber ring makes
contact, then tighten 1/2 turn more.
4. Start the unit and check for leaks.
Summary of Contents for SB-210
Page 4: ...4 ...
Page 12: ...List of Figures 12 ...
Page 31: ...Unit Description 31 Unit Photos Figure 6 Front View AJA1617 ...
Page 36: ...Unit Description 36 ...
Page 49: ...Operating Instructions 49 Figure 32 Viewing Sensors Screen Sequence ...
Page 54: ...Operating Instructions 54 Figure 40 Datalogger Screen Sequence ...
Page 101: ...Engine Maintenance 101 ...
Page 102: ...Engine Maintenance 102 ...
Page 140: ...Electric Standby Diagnosis 140 ...
Page 150: ...Index 150 ...
Page 152: ...Wiring Diagram Index 152 ...
Page 153: ...153 Model 30 and 50 Schematic Diagram Page 1 of 3 ...
Page 154: ...154 Model 30 and 50 Schematic Diagram Page 2 of 3 ...
Page 155: ...155 Model 30 and 50 Schematic Diagram Page 3of 3 ...
Page 156: ...156 Model 30 and 50 Wiring Diagram Page 1 of 4 ...
Page 157: ...157 Model 30 and 50 Wiring Diagram Page 2 of 4 ...
Page 158: ...158 Model 30 and 50 Wiring Diagram Page 3 of 4 ...
Page 159: ...159 Model 30 and 50 Wiring Diagram Page 4 of 4 ...