Refrigeration Service Operations
119
Assembly/Installation
After cleaning and inspecting all parts, reassemble
the valve.
1. Install the screen in the bottom cap.
2. Install the new stem in the bottom cap.
3. Install new gaskets on both sides of the seat.
Oil the gaskets in compressor oil before
installing.
4. Use the three-way valve seal installation tool
P/N 204-1008 to install a new seal on the
piston. This prevents the seal from being
stretched and damaged.
a. Place the tapered tool over the piston.
b. Lubricate the seal with refrigeration oil.
c. Slide the seal onto the tapered tool with
the spring side facing away from the
piston.
d. Use the pipe to hand press the seal onto
the piston.
5. Place the piston slot on the stem and secure
with spring clip. The open part of the clip
should be on the opposite side of the piston
slot.
6. Install the spring and end cap.
7. Line up the passageways in the cap and body.
Failure to line up the holes will result in
improper operation of the valve.
8. Install the bolts and tighten in rotating
sequence. Torque to 160 in-lb (18 N•m).
9. Install the pilot solenoid line and pressurize
the system with refrigerant to check for leaks.
10. If there are no leaks, evacuate the system and
recharge with the proper refrigerant.
11. Run the unit to check for proper three-way
valve operation.
Three-Way Valve Condenser
Pressure Bypass Check Valve
Repair
Removal
1. Recover the refrigerant charge.
2. Unscrew the condenser pressure bypass check
valve cap from the three-way valve.
3. Remove the snap ring.
4. Unscrew the check valve stem by using a
screwdriver in the slot provided.
NOTE: The spring and piston are held in by
the stem. While removing the stem, use care
so the spring and piston are not lost.
5. Remove the spring and piston.
1.
Press by Hand
4.
Tapered Tool
2.
Pipe
5.
Piston
3.
Seal
Figure 106: Seal Installation with Tool P/N 204-1008
1
ARA166
2
3
4
5
1.
Piston
4.
Stem
2.
Snap Ring
5.
O-ring
3.
Cap
6.
Spring
Figure 107: Teflon Check Valve Assembly
AEA715
Summary of Contents for SB-210
Page 4: ...4 ...
Page 12: ...List of Figures 12 ...
Page 31: ...Unit Description 31 Unit Photos Figure 6 Front View AJA1617 ...
Page 36: ...Unit Description 36 ...
Page 49: ...Operating Instructions 49 Figure 32 Viewing Sensors Screen Sequence ...
Page 54: ...Operating Instructions 54 Figure 40 Datalogger Screen Sequence ...
Page 101: ...Engine Maintenance 101 ...
Page 102: ...Engine Maintenance 102 ...
Page 140: ...Electric Standby Diagnosis 140 ...
Page 150: ...Index 150 ...
Page 152: ...Wiring Diagram Index 152 ...
Page 153: ...153 Model 30 and 50 Schematic Diagram Page 1 of 3 ...
Page 154: ...154 Model 30 and 50 Schematic Diagram Page 2 of 3 ...
Page 155: ...155 Model 30 and 50 Schematic Diagram Page 3of 3 ...
Page 156: ...156 Model 30 and 50 Wiring Diagram Page 1 of 4 ...
Page 157: ...157 Model 30 and 50 Wiring Diagram Page 2 of 4 ...
Page 158: ...158 Model 30 and 50 Wiring Diagram Page 3 of 4 ...
Page 159: ...159 Model 30 and 50 Wiring Diagram Page 4 of 4 ...