Operating Instructions
53
Datalogger Menu
The SR-2 controller is equipped with datalogging
capability. Datalogging can store trip information
for later use. A “Start of Trip” is initiated to
accurately store information,.
Trip data is logged as follows:
ServiceWatch™:
ServiceWatch is standard
equipment. It is an integrated datalogging system
that records operating events, alarm codes and
compartment temperatures as they occur and at
preset intervals.
CargoWatch™:
CargoWatch is an optional
datalogger system that logs data of up to six
temperature sensor/probes, four door switches,
humidity sensor, data averaging, and
programmable, temperature out of range alarms.
Initiating a Start of Trip
A “Start Of Trip” places a marker in the
datalogger memory. A Start Of Trip can be
initiated through the use of WinTrac datalogging
software, or manually in the field. The following
procedure covers manual initiation. For more
information on datalogging, see the WinTrac
Datalogging Software Operating Manual.
1. Start at the Standard Display. If the
Temperature Watch Display is showing, press
the
M
ENU
soft key once to return to the
Standard Display. See Figure 39.
2. Press the
M
ENU
soft key on the Standard
Display.
3. Press the
N
EXT
soft key until the Datalogger
Menu appears. See Figure 40.
4. Press the
S
ELECT
soft key on the Datalogger
Menu. The “Start Trip” Screen will appear.
5. Press the
S
ELECT
soft key. The “Start Of Trip”
Screen will appear.
6. Press the
S
ELECT
soft key to initiate a start of
trip.
7. A Start Of Trip Marker has been inserted into
the datalogger memory.
Printing a Trip Report
This procedure prints the current datalogger
record directly to a handheld printer. Only data
from the sensors connected to the HMI Cargo
Watch data logger can be printed. Graphs are not
available with a handheld printer.
1. Connect the printer to the printer port in the
control box.
2. Start at the Standard Display. If the
Temperature Watch Display is showing, press
the
M
ENU
soft key once to return to the
Standard Display. See Figure 39.
3. Press the
M
ENU
soft key on the Standard
Display.
4. Press the
N
EXT
soft key until the Datalogger
Menu appears. See Figure 40.
5. Press the
S
ELECT
soft key on the Datalogger
Menu. The “Start Trip” Screen will appear.
6. Press the
N
EXT
soft key. The “Print/View”
Screen will appear.
7. Press the
S
ELECT
soft key. The “Delivery
Ticket” Screen will appear. Press the
S
ELECT
soft key to print a delivery report.
8. Press the
N
EXT
soft key to go to the “Trip
Ticket” Screen. Press the
S
ELECT
soft key to
print a trip report.
1.
Menu Soft Key
Figure 39: Standard Display
1
Summary of Contents for SB-210
Page 4: ...4 ...
Page 12: ...List of Figures 12 ...
Page 31: ...Unit Description 31 Unit Photos Figure 6 Front View AJA1617 ...
Page 36: ...Unit Description 36 ...
Page 49: ...Operating Instructions 49 Figure 32 Viewing Sensors Screen Sequence ...
Page 54: ...Operating Instructions 54 Figure 40 Datalogger Screen Sequence ...
Page 101: ...Engine Maintenance 101 ...
Page 102: ...Engine Maintenance 102 ...
Page 140: ...Electric Standby Diagnosis 140 ...
Page 150: ...Index 150 ...
Page 152: ...Wiring Diagram Index 152 ...
Page 153: ...153 Model 30 and 50 Schematic Diagram Page 1 of 3 ...
Page 154: ...154 Model 30 and 50 Schematic Diagram Page 2 of 3 ...
Page 155: ...155 Model 30 and 50 Schematic Diagram Page 3of 3 ...
Page 156: ...156 Model 30 and 50 Wiring Diagram Page 1 of 4 ...
Page 157: ...157 Model 30 and 50 Wiring Diagram Page 2 of 4 ...
Page 158: ...158 Model 30 and 50 Wiring Diagram Page 3 of 4 ...
Page 159: ...159 Model 30 and 50 Wiring Diagram Page 4 of 4 ...