Engine Maintenance
78
NOTE: The use of 50/50 percent pre-mixed
Extended Life Coolant (ELC) is recommended to
assure that de-ionized water is being used. If
100 percent full strength concentrate is used,
de-ionized or distilled water is recommended
over tap water to insure the integrity of the
cooling system is maintained.
Antifreeze Maintenance Procedure
As with all equipment containing antifreeze,
periodic inspection on a regular basis is required
to verify the condition of the antifreeze. Inhibitors
become worn out and must be replaced by
changing the antifreeze. Change ELC (red) engine
coolant every five years or 12,000 hours
(whichever occurs first).
Do not mix green or blue-green engine coolant
with ELC (red) engine coolant. See “ELC
(Extended Life Coolant)” for more information
about ELC.
The factory recommends the use of a 50/50
antifreeze mixture in all units even if they are not
exposed to freezing temperatures. This antifreeze
mixture will provide the required corrosion
protection and lubrication for the water pump.
Checking the Antifreeze
Check the solution concentration by using a
temperature compensated antifreeze hydrometer
or a refractometer (P/N 204-754) designed for
testing antifreeze. Maintain a minimum of 50
percent permanent type antifreeze concentrate and
50 percent water solution to provide protection to
-30 F (-34 C). Do not mix antifreeze stronger than
68 percent permanent type coolant concentrate
and 32 percent water for use in extreme
temperatures.
Changing the Antifreeze
1. Run the engine until it is up to its normal
operating temperature. Stop the unit.
2. Open the engine block drain (located behind
the starter) and completely drain the coolant.
Observe the coolant color. If the coolant is
dirty, proceed with a, b, and c. Otherwise go
to 3.
a. Run clear water into the radiator and allow
it to drain out of the block until it is clear.
b. Close the block drain and install a
commercially available radiator and block
flushing agent, and operate the unit in
accordance with instructions of the
flushing agent manufacturer.
c. Open the engine block drain to drain the
water and flushing solution.
3. Run clear water into the radiator, and allow it
to drain out of the block until it is clear.
4. Inspect all hoses for deterioration and hose
clamp tightness. Replace if necessary.
5. Loosen the water pump belt. Check the water
pump bearing for looseness.
6. Inspect the radiator cap. Replace the cap if the
gasket shows any signs of deterioration.
7. If using ELC concentrate, mix one gallon of
ELC concentrate and one gallon of de-ionized
or distilled water in a container to make a
50/50 mixture. (Do not add antifreeze and
then add water to the unit. This procedure may
not give a true 50/50 mixture because the
exact cooling system capacity may not always
be known.)
8. Refill the radiator with the 50/50 antifreeze
mixture and make sure to bleed the air from
the cooling system as needed.
CAUTION: Avoid direct contact with hot
coolant.
CAUTION: Avoid direct contact with hot
coolant.
Summary of Contents for SB-210
Page 4: ...4 ...
Page 12: ...List of Figures 12 ...
Page 31: ...Unit Description 31 Unit Photos Figure 6 Front View AJA1617 ...
Page 36: ...Unit Description 36 ...
Page 49: ...Operating Instructions 49 Figure 32 Viewing Sensors Screen Sequence ...
Page 54: ...Operating Instructions 54 Figure 40 Datalogger Screen Sequence ...
Page 101: ...Engine Maintenance 101 ...
Page 102: ...Engine Maintenance 102 ...
Page 140: ...Electric Standby Diagnosis 140 ...
Page 150: ...Index 150 ...
Page 152: ...Wiring Diagram Index 152 ...
Page 153: ...153 Model 30 and 50 Schematic Diagram Page 1 of 3 ...
Page 154: ...154 Model 30 and 50 Schematic Diagram Page 2 of 3 ...
Page 155: ...155 Model 30 and 50 Schematic Diagram Page 3of 3 ...
Page 156: ...156 Model 30 and 50 Wiring Diagram Page 1 of 4 ...
Page 157: ...157 Model 30 and 50 Wiring Diagram Page 2 of 4 ...
Page 158: ...158 Model 30 and 50 Wiring Diagram Page 3 of 4 ...
Page 159: ...159 Model 30 and 50 Wiring Diagram Page 4 of 4 ...