Structural Maintenance
131
8. De-energize and energize the damper several
times to make sure that the damper operates
correctly and seals properly.
9. Make sure the damper blade rests on the round
stops when the damper is open. Adjust the
round stops if necessary.
10. Install the damper assembly in the evaporator.
Condenser and Evaporator Fan
Location
When mounting the condenser or evaporator fan
and hub assembly on the fanshaft, the blowers and
inlet orifices must be properly aligned for proper
air flow and to prevent damage to the blower.
Condenser Fan Blower
1. Loosen the condenser inlet ring (spinning) on
the condenser coil bulkhead.
2. Slide the blower towards the inlet ring until it
contacts the inlet ring. This centers the inlet
ring in the blower orifice.
3. Tighten the inlet ring securely.
4. Slide the blower away from the inlet ring.
5. Pass a gauge wire completely around the
blower orifice to check for uniform clearance.
6. Spin the blower by hand to check for blower
distortion.
7. Position the blower so the edge of the inlet
ring lines up with the alignment mark on the
blower.
8. Torque blower hub bolts to 18 ft-lb (24 N•m).
Evaporator Fan Blower
1. Loosen the inlet rings on the sides of the
blower housing.
2. Center the blower wheel in the blower housing
with equal overlap on both inlet rings. The
overlap on each ring should be approximately
0.15 in. (3.8 mm).
3. Tighten the hub bolts that hold the blower
wheel on the fanshaft.
4. Center the inlet rings in the blower orifices.
Tighten the inlet rings securely.
5. Check the radial clearance by passing a wire
completely around the circumference of the
inlet rings and the blower wheel.
6. Torque the blower hub bolts to 18 ft-lb
(24 N•m).
1.
Blower Wheel
3.
Alignment Mark
2.
Inlet Ring
4.
Edge of Inlet Ring
Figure 118: Condenser Blower Alignment
1
2
3
4
AEA749
1.
Check Clearance with a Wire
2.
Blower Housing Sides
3.
Inlet Rings
4.
Evaporator Blower
5.
Radial Clearance
6.
Equalize Blower Inlet Overlap
Figure 119: Evaporator Fan Location
AEA720
Summary of Contents for SB-210
Page 4: ...4 ...
Page 12: ...List of Figures 12 ...
Page 31: ...Unit Description 31 Unit Photos Figure 6 Front View AJA1617 ...
Page 36: ...Unit Description 36 ...
Page 49: ...Operating Instructions 49 Figure 32 Viewing Sensors Screen Sequence ...
Page 54: ...Operating Instructions 54 Figure 40 Datalogger Screen Sequence ...
Page 101: ...Engine Maintenance 101 ...
Page 102: ...Engine Maintenance 102 ...
Page 140: ...Electric Standby Diagnosis 140 ...
Page 150: ...Index 150 ...
Page 152: ...Wiring Diagram Index 152 ...
Page 153: ...153 Model 30 and 50 Schematic Diagram Page 1 of 3 ...
Page 154: ...154 Model 30 and 50 Schematic Diagram Page 2 of 3 ...
Page 155: ...155 Model 30 and 50 Schematic Diagram Page 3of 3 ...
Page 156: ...156 Model 30 and 50 Wiring Diagram Page 1 of 4 ...
Page 157: ...157 Model 30 and 50 Wiring Diagram Page 2 of 4 ...
Page 158: ...158 Model 30 and 50 Wiring Diagram Page 3 of 4 ...
Page 159: ...159 Model 30 and 50 Wiring Diagram Page 4 of 4 ...