37
Operating Instructions
SMART REEFER 2 (SR-2)
Control System
The microprocessor components are located
inside the control box, which is located inside the
lower roadside service door. The microprocessor
is connected to an HMI (Human Machine
Interface) Control Panel. It is used to operate the
unit. The Cargo Watch and Service Watch ports
are used to retrieve data from the data logging
system.
Microprocessor On/Off Switch
This switch supplies or removes electrical power
to the microprocessor. It is located on the left side
of the control box.
HMI Control Panel
Use the HMI control panel to operate the unit.
Refer to the SB-210/310 Operator’s Manual
TK 51585 and the SR-2 Microprocessor Control
System Diagnostic Manual TK 51587 for more
information.
The HMI control panel has a display and eight
touch sensitive keys. The display is capable of
showing both text and graphics. The four keys on
the left and right sides of the display are dedicated
keys. The four keys under the display are “soft”
keys. The function of “soft” keys change
depending on the operation being performed. If a
soft key is active, its function will be shown in the
display directly above the key.
Figure 12: SR-2 HMI Control Panel
1.
Control Box
4.
Cargo Watch Port
2.
Microprocessor
On/Off Switch
5.
HMI Control Panel
3.
Service Watch Port
Figure 11: Control Box With Service Door Open
CAUTION: The microprocessor On/Off
switch must be placed in the Off position
before connecting or disconnecting the
battery or servicing the microprocessor
system.
5
2
1
3
4
CAUTION: The microprocessor is
vulnerable to damage from Electro Static
Discharge (ESD). This damage is not
always immediately apparent. As a result
of ESD, a circuit can be damaged but may
continue to operate temporarily, only to
fail later.
AJA1956
Summary of Contents for SB-210
Page 4: ...4 ...
Page 12: ...List of Figures 12 ...
Page 31: ...Unit Description 31 Unit Photos Figure 6 Front View AJA1617 ...
Page 36: ...Unit Description 36 ...
Page 49: ...Operating Instructions 49 Figure 32 Viewing Sensors Screen Sequence ...
Page 54: ...Operating Instructions 54 Figure 40 Datalogger Screen Sequence ...
Page 101: ...Engine Maintenance 101 ...
Page 102: ...Engine Maintenance 102 ...
Page 140: ...Electric Standby Diagnosis 140 ...
Page 150: ...Index 150 ...
Page 152: ...Wiring Diagram Index 152 ...
Page 153: ...153 Model 30 and 50 Schematic Diagram Page 1 of 3 ...
Page 154: ...154 Model 30 and 50 Schematic Diagram Page 2 of 3 ...
Page 155: ...155 Model 30 and 50 Schematic Diagram Page 3of 3 ...
Page 156: ...156 Model 30 and 50 Wiring Diagram Page 1 of 4 ...
Page 157: ...157 Model 30 and 50 Wiring Diagram Page 2 of 4 ...
Page 158: ...158 Model 30 and 50 Wiring Diagram Page 3 of 4 ...
Page 159: ...159 Model 30 and 50 Wiring Diagram Page 4 of 4 ...