Other master continues
S
SLA/R
A
DATA
A
P
1) UCTR=0 (Receiver)
2) UCTXSTT=1
Successful
reception from a
slave transmitter
UCRXIFG=1
DATA
DATA
A
UCTXSTP=1
Next transfer started
with a repeated start
condition
DATA
S
SLA/W
1) UCTR=1 (Transmitter)
2) UCTXSTT=1
DATA
S
SLA/R
1) UCTR=0 (Receiver)
2) UCTXSTT=1
Not acknowledge
received after slave
address
UCTXSTT=0
UCNACKIFG=1
P
S
SLA/W
S
SLA/R
1) UCTR=1 (Transmitter)
2) UCTXSTT=1
1) UCTR=0 (Receiver)
2) UCTXSTT=1
Arbitration lost in
slave address or
data byte
A
Other master continues
UCALIFG=1
UCMST=0
Arbitration lost and
addressed as slave
Other master continues
A
UCALIFG=1
UCMST=0
UCTR=1 (Transmitter)
UCSTTIFG=1
UCTXIFG=1
USCI continues as Slave Transmitter
A
A
A
UCTXSTT=0
UCTXSTP=0
UCTXIFG=1
UCALIFG=1
UCMST=0
UCTXSTP=1
UCTXSTP=0
eUSCI_B Operation – I
2
C Mode
Figure 20-13. I
2
C Master Receiver Mode
545
SLAU272C – May 2011 – Revised November 2013
Enhanced Universal Serial Communication Interface (eUSCI) – I
2
C Mode
Copyright © 2011–2013, Texas Instruments Incorporated