eUSCI_A UART Registers
18.4.8 UCAxABCTL Register
eUSCI_Ax Auto Baud Rate Control Register
Figure 18-19. UCAxABCTL Register
15
14
13
12
11
10
9
8
Reserved
r-0
r-0
r-0
r-0
r-0
r-0
r-0
r-0
7
6
5
4
3
2
1
0
Reserved
UCDELIMx
UCSTOE
UCBTOE
Reserved
UCABDEN
r-0
r-0
rw-0
rw-0
rw-0
rw-0
r-0
rw-0
Modify only when UCSWRST = 1
Table 18-15. UCAxABCTL Register Description
Bit
Field
Type
Reset
Description
15-6
Reserved
R
0h
Reserved
5-4
UCDELIMx
RW
0h
Break/synch delimiter length
00b = 1 bit time
01b = 2 bit times
10b = 3 bit times
11b = 4 bit times
3
UCSTOE
RW
0h
Synch field time out error
0b = No error
1b = Length of synch field exceeded measurable time.
2
UCBTOE
RW
0h
Break time out error
0b = No error
1b = Length of break field exceeded 22 bit times.
1
Reserved
R
0h
Reserved
0
UCABDEN
RW
0h
Automatic baud-rate detect enable
0b = Baud-rate detection disabled. Length of break and synch field is not
measured.
1b = Baud-rate detection enabled. Length of break and synch field is measured
and baud-rate settings are changed accordingly.
500
Enhanced Universal Serial Communication Interface (eUSCI) – UART Mode
SLAU272C – May 2011 – Revised November 2013