Instruction Set Description
4.6.2.21 INC
* INC[.W]
Increment destination
* INC.B
Increment destination
Syntax
INC dst
or
INC.W dst
INC.B dst
Operation
dst + 1
→
dst
ADD #1,dst
Emulation
Description
The destination operand is incremented by one. The original contents are lost.
Status Bits
N:
Set if result is negative, reset if positive
Z:
Set if dst contained 0FFFFh, reset otherwise
Set if dst contained 0FFh, reset otherwise
C:
Set if dst contained 0FFFFh, reset otherwise
Set if dst contained 0FFh, reset otherwise
V:
Set if dst contained 07FFFh, reset otherwise
Set if dst contained 07Fh, reset otherwise
Mode Bits
OSCOFF, CPUOFF, and GIE are not affected.
Example
The status byte, STATUS, of a process is incremented. When it is equal to 11, a branch
to OVFL is taken.
INC.B
STATUS
CMP.B
#11,STATUS
JEQ
OVFL
154
CPUX
SLAU272C – May 2011 – Revised November 2013
Copyright © 2011–2013, Texas Instruments Incorporated