Terry Melody 1 - Installation Instructions - ED01050g
33
ref: ED01067a, dated: 07/06/2006
MELODY 1 MEGGER TESTING
Earth continuity test
1)
Referencing pages 25 (Wiring Diagram), and 27(Control Board Layout) of this
Document, disconnect the 6 way male connector and Red and Grey flying
leads associated with the 8 core cable (#2 Charger Box Interface), the 7way
male connector (#3 Carriage Call Station), and the 3 way male connector (#4
Lower Wall Station and # 5) from the main loom.
2)
At the charge box, remove the 7 and 8 core cable connectors from the main
charge box connectors and the flying Grey Core.
3)
With reference to page 25, megger test between the following terminals of
the 6 way male connector (8 Core Cable to Charger Box).
From W to BK,BL,BN,R and G,
From BK to BL,BN,R and G
From BL to BN,R and G
From BN to R and G
From R to G
4)
Before completing the following test of the Carriage Call Station Cable it
is essential that the Call Station is disconnected from its 7 Core Cable.
Failure to complete this action will result in LED’s with the call station
being destroyed.
From W to BK, BL, BN, R and G
From BK to BL, BN, R and G
From BL to BN, R and G
From BN to R and G
From R to G
5)
Before completing the following test of the Lower Wall Station Cable it
is essential that the Wall Station is disconnected from its 7 Core Cable.
Failure to complete this action will result in LED’s and switched with the
call station being destroyed.
From BK, BL, R and G
From BL, R and G
From R and G
6)
Before completing the following test of the Upper Wall Station and
Upper Level Door Cables it is essential that the Upper Wall Station
and Upper Level Gate 7 Core cable connector blocks be disconnected.
Failure to complete this action will result in LED’s with the call station
being destroyed.
From W to BK, BL, BN, R and G
From BK to BL, BN, R and G
From BL to BN, R and G
From BN to R and G
From R to G
7)
Disconnect the 13 way female connector from TB1 of the Modified CE1080
board, and remove the 25A Battery Fuse and 5 A Charge Fuse
8)
At the 13 Way connector , Megger between the following connections:
3 to 5, 7 and 11
From Up Ramp to other Circuits
5 to 7 and 11
From Top Limit to Other Circuits
7 to 11
From DN S/E to other circuits
9)
Replace all connections.
All megger readings should be > 1M Ohm.
NOTES
Summary of Contents for Melody 1
Page 1: ...Installation Manual Melody 1 Platform Lift Ref ED01050g Date 03 04 2012 Original instructions...
Page 18: ...Terry Melody 1 Installation Instructions ED01050g 18...
Page 20: ...Terry Melody 1 Installation Instructions ED01050g 20...
Page 22: ...Terry Melody 1 Installation Instructions ED01050g 22...
Page 26: ...Terry Melody 1 Installation Instructions ED01050g 26...
Page 28: ...Terry Melody 1 Installation Instructions ED01050g 28...
Page 34: ...Terry Melody 1 Installation Instructions ED01050g 34...
Page 36: ...Terry Melody 1 Installation Instructions ED01050g 36...
Page 60: ...Terry Melody 1 Installation Instructions ED01050g 60...
Page 66: ...Terry Melody 1 Installation Instructions ED01050g 66...