MELODY 1 GENERAL FAULT FINDING
FAULT
CHECK
Lift will not go up
Check that when the up button is pressed, is L1 (green
LED) lit ?
If not :-
1. Check platform gate
2. Check F1 fuse (25A)
3. Check isolate switch on charger box is in.
4. Check remote control enabler operation.(if fitted).
If above is OK, check wiring.
Lift will not go
down
Check when the down button is pressed, is L2 (yellow
LED) lit ?
If not :-
1. Check final limit switch
2. Check F2 fuse (5 A)
If above is OK, check wiring
3. Check isolate switch on charger box is in.
4. Check remote control enabler operation (if fitted).
If above is OK, check wiring .
Lift will not go up
or down
(L1 and L2 not lit)
1. Check F3 (1A) is OK
2. Check lift isolate fuse (30A) is OK
3. Check battery voltage - should be in the range 27.5
– 29.5V(from charger) – if not -
4. Check 5A fuse to charger – if OK change charger
5. Check for bowden cable failure
6. Check that upper level gate (if fitted) is closed.
Upper level gate
will not open
1. Check that lift is at the top.
Note: Gate will only be opened within the first five-ten
seconds of the lift reaching the top level. If timer has
expired the gate can be released by pressing and re-
leasing gate release switch, unless on the lift in which
case the lift will have to be sent down and brought back
up to the top to open the gate.
Lower level gate will
not open
2. Check that lift is at the bottom.
Note: Gate will only be opened within the first five-ten
seconds of the lift reaching the bottom level. If timer has
expired the gate can be released by pressing and releasing
the carriage or lower post gate release switch, unless on
the lift in which case the lift will have to be sent down and
brought back up to the top to open the gate.
Reprogramming
the remote control
enabler key fob
It maybe necessary to reprogram the key fobs if the
lift has been disconnected from the mains or been in
storage for a long time. Full instructions to reprogram
the key fob including the 3 minute timer feature are at-
tached. See page 22
NOTES
Summary of Contents for Melody 1
Page 1: ...Installation Manual Melody 1 Platform Lift Ref ED01050g Date 03 04 2012 Original instructions...
Page 18: ...Terry Melody 1 Installation Instructions ED01050g 18...
Page 20: ...Terry Melody 1 Installation Instructions ED01050g 20...
Page 22: ...Terry Melody 1 Installation Instructions ED01050g 22...
Page 26: ...Terry Melody 1 Installation Instructions ED01050g 26...
Page 28: ...Terry Melody 1 Installation Instructions ED01050g 28...
Page 34: ...Terry Melody 1 Installation Instructions ED01050g 34...
Page 36: ...Terry Melody 1 Installation Instructions ED01050g 36...
Page 60: ...Terry Melody 1 Installation Instructions ED01050g 60...
Page 66: ...Terry Melody 1 Installation Instructions ED01050g 66...