Operations Manual: ASCII Command/Response Structure
Engineered to Endure
TPM
Description: Displays or configures the power monitoring mode of the Cyber
Hardened IBUC
2
, IBUC
2e
, IBUC
2
G
, IBUC
R
or IBUC
G
. When configured for
burst, TBT must also be set. Default values for the TBT command are given in
. If CW is selected power is read continuously. If burst is
selected the power reading only changes when a valid burst is detected.
Parameter:
<Value>
0 = CW / 1 = Burst
TPO
Description: Displays the current output power of the Cyber Hardened IBUC
2
,
IBUC
2e
, IBUC
2
G
, IBUC
R
or IBUC
G
. If TPM is set to burst, this will be the last
valid burst sample of the output power. Use the TFR command to configure the
desired frequency to be monitored. This is a read
-
only command.
Parameter:
<xx.xx>
Current output power [decimal number]
Q
Query: TPM
Response: TPM=<Value>
C
Command: TPM=<Value>
Response: TPM=<Value>
Q
Query: TPO
Response: Tx Output Power=<xx.xx> dBm
Summary of Contents for IBUC 2
Page 6: ...iv Engineered to Endure Appendix F Glossary Glossary of Terms F 1 ...
Page 8: ...vi Engineered to Endure ...
Page 12: ...4 Engineered to Endure ...
Page 46: ...System Components 2 26 Engineered to Endure Figure 2 10 DC Power IBUC System Configuration ...
Page 57: ...General Requirements 3 9 Engineered to Endure Figure 3 2 IBUC 2 Field Installation ...
Page 196: ...I n d e x 4 ...