Operations Manual: Embedded Web Pages
Engineered to Endure
• Input Threshold Low Suppressible
Sets whether the lower input threshold is suppressible. Options include:
•
Disable
•
Enable
• Output Threshold Low Suppressible
Sets whether the lower output threshold is suppressible. Options include:
•
Disable
•
Enable
• Output Threshold High Suppressible
Sets whether the higher output threshold is suppressible. Options include:
•
Disable
•
Enable
• High Temperature Shutdown
Sets whether to shutdown the IBUC when the internal temperature threshold of
85° C has been exceeded. The unit must cool down by 20° C before resuming
transmission. Transmission will resume automatically once the unit has cooled by
20° C. Options include:
•
Disable
•
Enable (default)
• Suppress faults
Sets whether the unit will suppress all alarms that are configured as suppressible.
Options include:
•
Disable
•
Enable
• Simulate faults
When enabled, a simulated alarm is issued that does not affect transmission status
or traffic. Options include:
•
Disable
•
Enable
Use this alarm to determine whether your alarm settings are functional.