M&C Interfaces
|
5-5
Engineered to Endure
SNMPv3
The IBUC supports SNMP version 3.0 protocol. The SNMPv3 agent listens on Port
161 for SNMP messages and uses Port 162 for transmitting Trap information.
SNMPv3 can be configured from the RS232 and SSHv2.
The following commands configure SNMPv3 operation on the IBUC:
1. Establish a connection with the Cyber Hardened IBUC
2
, IBUC
2e
, IBUC
2
G
,
IBUC
R
or IBUC
G
.
2. Make sure that both SNMPv3 interface and SNMPv3 Trap functionality are
disabled. To disable SNMPv3 interface use the
. To disable SNMPv3 Trap functionality use the command
,
described on
.
Note:
Terrasat, Inc. Cyber Hardened IBUC’s come with two preconfigured SNMPv3
users. The first is “auth_no_priv”, which is destined for read-only access levels.
The second user is “auth_priv”, which is used for read-write operations. Both users
configurations are further described below:
“auth_no_priv”
•
Username: auth_no_priv
•
Authentication: MD5
•
Auth. Password: 12345678 (default)
“auth_priv”
•
Username: auth_priv
•
Authentication: MD5
•
Auth. Password: 12345678 (default)
•
Encryption: DES
•
Priv. Password: 12345678 (default)
Summary of Contents for IBUC 2
Page 6: ...iv Engineered to Endure Appendix F Glossary Glossary of Terms F 1 ...
Page 8: ...vi Engineered to Endure ...
Page 12: ...4 Engineered to Endure ...
Page 46: ...System Components 2 26 Engineered to Endure Figure 2 10 DC Power IBUC System Configuration ...
Page 57: ...General Requirements 3 9 Engineered to Endure Figure 3 2 IBUC 2 Field Installation ...
Page 196: ...I n d e x 4 ...