![Terrasat IBUC 2 Operation Manual Download Page 34](http://html.mh-extra.com/html/terrasat/ibuc-2/ibuc-2_operation-manual_1089881034.webp)
2-14
|
Cyber Hardened IBUC
2
,
IBUC
2e
,
IBUC
2
G
,
IBUC
R
,
IBUC
G
Operations Manual: Functional Description
Engineered to Endure
Note:
(G) marker stands for IBUC models that use GaN technology for power amplification
and required different fuses than regular GaAs amplifiers
Note:
For IBUCs that require fuses up to 6.3 A, Terrasat recommends time lag fuse with a
high I
2
t value. For IBUCs that require fuses greater than 6.3 A, Terrasat recommends
time-delay fuses.
For reference, IBUCs are delivered with one of the following Littelfuse Series fuse:
Ku
-
band
4 W
T1.6AL250V
T1.6AL250V
8 W
T2.5AL250V
T1.6AL250V
12 W
T2.5AL250V
T1.6AL250V
16 W
T3.15AL250V
T1.6AL250V
20 W
T4AL250V
T2AL250V
25 W
T5AL250V
T2.5AL250V
30 W
T8AL250V
T4AL250V
40 W
T8AL250V
T4AL250V
50 W
T10AL250V
T5AL250V
50 W(G)
T6.3AL250V
T3.15AL250V
60 W
T12.5AL250V
T6.3AL250V
80 W
T12.5AL250V
T6.3AL250V
80 W(G)
T10AL250V
T5AL250V
100 W
125 W
T16AL250V
T8AL250V
150 W(G)
N/A
T10AL250V
200 W
N/A
T20AH500V
200 W(G)
N/A
T10AL250V
300 W(G)
400 W(G)
N/A
T20AH500V
Ka
-
band
5 W(G)
T1.6AL250V
T1.6AL250V
10 W(G)
T2AL250V
T1.6AL250V
16 W(G)
20 W(G)
T3.15AL250V
T1.6AL250V
25 W(G)
T4AL250V
T2AL250V
40 W(G)
T6.3AL250V
T3.15AL250V
45 W(G)
T8AL250V
T4AL250V
80 W(G)
T10AL250V
T5AL250V
Table 2.7
Fuse Markings (Continued)
Signal
Power Level
Fuse Markings
115 VAC
230 VAC
Summary of Contents for IBUC 2
Page 6: ...iv Engineered to Endure Appendix F Glossary Glossary of Terms F 1 ...
Page 8: ...vi Engineered to Endure ...
Page 12: ...4 Engineered to Endure ...
Page 46: ...System Components 2 26 Engineered to Endure Figure 2 10 DC Power IBUC System Configuration ...
Page 57: ...General Requirements 3 9 Engineered to Endure Figure 3 2 IBUC 2 Field Installation ...
Page 196: ...I n d e x 4 ...