Operations Manual: Installation
Engineered to Endure
Optional mounting brackets are available that aid in attachment to antennas. The
mounting slots identified in
give you additional flexibility
when attaching the IBUC to the antenna.
Note:
Ensure that the threads of the bolts used for mounting the IBUC have been dipped in
the included Permatex anti
-
seize lubricant. This prevents galling, seizing, and
corrosion of fasteners during assembly and will aid in future disassembly. For more
information about applying the Permatex lubricant, see
.
Figure 3.6
Location of Adjustment Slots on Optional Mounting Bracket
System Pressurization
The IBUC chassis contains a breather valve (the location is identified in
) that is designed to equalize pressure inside and outside of the
unit while allowing the passage of air or water vapor but not environmental
contaminants such as liquids, debris, or dust. If you intend to pressurize the
waveguide, you must install a pressure window at the output of the IBUC; otherwise
the breather valve will not permit pressurization of the system.
Note:
IBUC units designed for Ka-band operation have pressure window already installed at
the output of the IBUC and are able to operate with pressurized waveguide
configurations.
Summary of Contents for IBUC 2
Page 6: ...iv Engineered to Endure Appendix F Glossary Glossary of Terms F 1 ...
Page 8: ...vi Engineered to Endure ...
Page 12: ...4 Engineered to Endure ...
Page 46: ...System Components 2 26 Engineered to Endure Figure 2 10 DC Power IBUC System Configuration ...
Page 57: ...General Requirements 3 9 Engineered to Endure Figure 3 2 IBUC 2 Field Installation ...
Page 196: ...I n d e x 4 ...