Cyber Hardened IBUC Console and SSHv2 Command Set
|
C-35
Engineered to Endure
TAZ
Description: Enables the suppression of any alarms configured as suppressible.
Parameter:
<Setting>
0 = no suppression / 1 = suppress configured alarms
TBH
Description: Display or configure the input power high alarm threshold. This setting
must be greater than the TBL setting.
Parameters:
<Value>
Input power high alarm threshold [-60 dBm to -15 dBm]
Q
Query: TAZ
Response: TAZ=<Setting>
C
Command: TAZ=<Setting>
Response: TAZ=<Setting>
Q
Query: TBH
Response: TBH=<Value>
C
Command: TBH=<Value>
Response: TBH=<Value>