![Terrasat IBUC 2 Operation Manual Download Page 148](http://html.mh-extra.com/html/terrasat/ibuc-2/ibuc-2_operation-manual_1089881148.webp)
C-20
|
Cyber Hardened IBUC
2
,
IBUC
2e
,
IBUC
2
G
,
IBUC
R
,
IBUC
G
Operations Manual: ASCII Command/Response Structure
Engineered to Endure
CSF
Description: Display or configure the IBUC for an input AC frequency of 50/60 Hz.
This command only applies to AC powered IBUCs..
Parameters:
<AC Frequency>
0 = 60 Hz / 1 = 50 Hz
CTI
Description: Display internal 10 MHz source installed..
Parameters:
<Value>
0 = Not Installed / 1 = Installed
Q
Query: CSF
Response: CSF=<AC Frequency>
C
Command: CSF=<AC Frequency>
Response: CSF=<AC Frequency>
Q
Query: CTI
Response: CTI=<Value>
Summary of Contents for IBUC 2
Page 6: ...iv Engineered to Endure Appendix F Glossary Glossary of Terms F 1 ...
Page 8: ...vi Engineered to Endure ...
Page 12: ...4 Engineered to Endure ...
Page 46: ...System Components 2 26 Engineered to Endure Figure 2 10 DC Power IBUC System Configuration ...
Page 57: ...General Requirements 3 9 Engineered to Endure Figure 3 2 IBUC 2 Field Installation ...
Page 196: ...I n d e x 4 ...