Cyber Hardened IBUC Console and SSHv2 Command Set
|
C-39
Engineered to Endure
TFI
Description: Displays the spectral inversion for this Cyber Hardened IBUC
2
,
IBUC
2e
, IBUC
2
G
, IBUC
R
or IBUC
G
. This is a read
-
only command.
Parameters:
<Value>
0 = Non-inverted (low side LO) / 1 = Inverted (high side LO)
TFR
Description: Displays or sets the output power monitor frequency of the Cyber
Hardened IBUC
2
, IBUC
2e
, IBUC
2
G
, IBUC
R
or IBUC
G
. The default values in
are listed according to the model number of the Cyber
Hardened IBUC. The command only increases the accuracy of the displayed power
levels.
Parameter:
<Frequency>
Which IF or RF frequency (in MHz) to monitor is based upon the frequency band
of the IBUC. IF will be automatically converted to RF.
Q
Query: TFI
Response: TFI=<Value>
Q
Query: TFR
Response: TFR=<Frequency>
C
Command: TFR=<Frequency>
Response: TFR=<Frequency>