System Components
|
2-6
Engineered to Endure
Table 2.4
IBUC
R
Transmit Frequency Plans
Signal
Standard C-band
Palapa C-band
Insat C-band
Extended C-band
Full C-band
L-band
(Inverting)
950 MHz to 1525 MHz
975 MHz to 1275 MHz
1150 MHz to 1450 MHz
950 MHz to 1750 MHz
975 MHz to 1850 MHz
LO frequency
(Inverting)
7.375 GHz
7.700 GHz
8.175 GHz
7.600 GHz
7.700 GHz
L-band
(Non-Inverting)
950 MHz to 1525 MHz
1125 MHz to 1425 MHz
965 MHz to 1265 MHz
950 MHz to 1750 MHz
950 MHz to 1825 MHz
LO frequency
(Non-Inverting)
4900 MHz
5300 MHz
5760 MHz
4900 MHz
4900 MHz
RF frequency
5.850 GHz to 6.425 GHz
6.425 GHz to 6.725 GHz
6.725 GHz to 7.025 GHz
5.850 GHz to 6.650 GHz
5.850 GHz to 6.725 GHz
Output Power
100, 125, 150, 175, 200,
400 watts
100, 125, 150, 175, 200 watts
100, 125, 150, 175, 200 watts
100, 125, 150, 175, 200 watts
100, 125, 150, 175, 200 watts
Signal
X-band
Standard Ku-band (Band1)
Full Ku-band (Band 2)
Low Ku-band (Band 3)
L-band
950 MHz to 1450 MHz
950 MHz to 1450 MHz
950 MHz to 1700 MHz
950 MHz to 1450 MHz
LO frequency
(Inverting)
—
—
—
—
LO frequency
(Non-Inverting)
6.950 GHz
13.050 GHz
12.800 GHz
11.800 GHz
RF frequency
7.900 GHz to 8.400 GHz
14.000 GHz to 14.500 GHz
13.750 GHz to 14.500 GHz
12.750 GHz to 13.250 GHz
Output Power
80, 100, 125, 150, 175 watts
60, 80, 100, 200 watts
60, 80,100, 200 watts
60, 80, 100, 125, 200 watts
Summary of Contents for IBUC 2
Page 6: ...iv Engineered to Endure Appendix F Glossary Glossary of Terms F 1 ...
Page 8: ...vi Engineered to Endure ...
Page 12: ...4 Engineered to Endure ...
Page 46: ...System Components 2 26 Engineered to Endure Figure 2 10 DC Power IBUC System Configuration ...
Page 57: ...General Requirements 3 9 Engineered to Endure Figure 3 2 IBUC 2 Field Installation ...
Page 196: ...I n d e x 4 ...