3-6
|
Cyber Hardened IBUC
2
,
IBUC
2e
,
IBUC
2
G
,
IBUC
R
,
IBUC
G
Operations Manual: Installation
Engineered to Endure
All IBUCs that are AC
-
powered and all Terrasat outdoor PSUI’s are furnished with a
detachable AC power connector that is used to connect and disconnect power. When
connecting the AC connector to the AC power source, the wiring must include a 15 A
or 20 A circuit breaker. A disconnect device (such as a circuit breaker or mains supply
plug on the power supply cord) that is readily accessible must also be provided. Any
outdoor AC connections should be made using suitable connectors or boxes with an
IEC protection class of at least IP65.
If a circuit breaker is not easily accessible as a disconnecting device, the input
connector will be the disconnecting device. In this case, the socket-outlet must be
installed near the equipment and must be easily accessible for pluggable equipment.
All AC
-
powered IBUCs and the Terrasat outdoor PSUI are furnished with mating
connectors for the AC mains power cable. To remain compliant with European Low
Voltage Directive (EN 60950-1), use a power cable that meets IEC 60227
requirements such as HAR Cable Designation H03VV
-
F or H03VVH2
-
F and/or
Table 3.2
Terrasat Outdoor Power Supplies
Model
Output Power
Application
PSUI-948-0250S-4
250 W
• C-band up to 25 W
• X-band up to 25 W
• Ku-band up to 16 W
• Ka-band up to 16 W
PSUI-948-600-4
600 W
• C-band up to 80 W
• X-band up to 80 W
• Ku-band up to 50 W
• Ka-band up to 40 W
PSUI-948-1000-4
1000 W
• C-band 100 W to 125 W
• X-band 100 W to 125 W
• Ku-band 60 W to 80 W
PSUI-948-600-4
1200 W
• C-band 150 W to 200 W
• X-band 150 W to 175 W
!
WARNING
Ensure AC power is off when connecting or disconnecting the power
supply unit's power cord. To turn off AC power to the unit, use the
installed circuit breaker or a similar disconnecting device.
Summary of Contents for IBUC 2
Page 6: ...iv Engineered to Endure Appendix F Glossary Glossary of Terms F 1 ...
Page 8: ...vi Engineered to Endure ...
Page 12: ...4 Engineered to Endure ...
Page 46: ...System Components 2 26 Engineered to Endure Figure 2 10 DC Power IBUC System Configuration ...
Page 57: ...General Requirements 3 9 Engineered to Endure Figure 3 2 IBUC 2 Field Installation ...
Page 196: ...I n d e x 4 ...