Cyber Hardened IBUC Console and SSHv2 Command Set
|
C-7
Engineered to Endure
CCF
Description: Display the power offset between the RF output and the sample port.
CCF is not available unless the IBUC has a sample port. This query returns the offset
for the frequency configured with TFR.
Parameter:
<Offset>
Offset between the RF output and the sample port [decimal number in dB]
CBT
Description: Display or configure the longest allowable time between valid data bursts
before the IBUC reports an alarm. This command applies when the IBUC is set to
burst power monitoring.
Parameters:
<Timeout>
timeout value in seconds [0 to 300]. A value of 0 means no timeout
Q
Query: CCF
Response: CCF=<Offset>
Q
Query: CBT
Response: CBT=<Timeout>
C
Command: CBT=<Timeout>
Response: CBT=<Timeout>