Operations Manual: Embedded Web Pages
Engineered to Endure
• Output Threshold High
Sets the highest permitted transmit input value up to (rated P1dB+ 1 dB). You will
receive an error message if you try to exceed the threshold range. Click
OK
to
return to the Tx Config page to enter a valid value.
• Internal 10 MHz Trim
You can specify a frequency trimming value for IBUCs equipped with optional
internal 10 MHz reference signal.
Valid values: 0-4095
Note:
When the IBUC is operating using an external 10 MHz reference signal, this field
is grayed-out and unavailable for user input.
Interface Configuration Tab
Use this tab to configure the interfaces (TCP/IP) for the Cyber Hardened IBUC
2
,
IBUC
2e
, IBUC
2
G
, IBUC
R
and IBUC
G
. Click
Submit
when you have
completed entering data to ensure that your changes are saved and implemented.
Figure B.10
Interface Configuration Tab
From this page you can configure the following parameters:
• IP Address
Valid values range from (but do not include) 1.0.0.0 through 224.0.0.0. When the
netmask is applied, 0 and 225 in the last byte are excluded.
• IP Subnet Mask
Sets the IP netmask.
•
Valid values range from 8 through 30 representing the number of ones in the
netmask. This corresponds to 22.0.0.0 to 255.255.255.252.
• Gateway Address
Sets the IP Gateway Address which is the address that the IBUC will send to if the
requested IP address does not reside on the local LAN segment.
Note:
This address cannot be the same as the IP address of the unit.
SNMPv3 settings
must be accessed via RS232
interface. Please refer to
for more information on configuring SNMPv3 settings.
Summary of Contents for IBUC 2
Page 6: ...iv Engineered to Endure Appendix F Glossary Glossary of Terms F 1 ...
Page 8: ...vi Engineered to Endure ...
Page 12: ...4 Engineered to Endure ...
Page 46: ...System Components 2 26 Engineered to Endure Figure 2 10 DC Power IBUC System Configuration ...
Page 57: ...General Requirements 3 9 Engineered to Endure Figure 3 2 IBUC 2 Field Installation ...
Page 196: ...I n d e x 4 ...