C-36
|
Cyber Hardened IBUC
2
,
IBUC
2e
,
IBUC
2
G
,
IBUC
R
,
IBUC
G
Operations Manual: ASCII Command/Response Structure
Engineered to Endure
TBL
Description: Display or configure the input power low alarm threshold. This setting
must be less than the TBH setting.
Parameters:
<Value>
Input power low alarm threshold [-60 dBm to -15 dBm]
TBT
Description: Displays or sets the burst threshold based upon the Cyber Hardened
IBUC
2
, IBUC
2e
, IBUC
2
G
, IBUC
R
or IBUC
G
Rated Power Level (RPL). See
. This command only applies if the IBUC is configured for burst power
monitoring.
Parameters:
<dBm>
Burst threshold [RPL – 20 dB to RPL + 1 dB]
Q
Query: TBL
Response: TBL=<Value>
C
Command: TBL=<Value>
Response: TBL=<Value>
Q
Query: TBT
Response: TBT=<dBm>
C
Command: TBT=<dBm>
Response: TBT=<dBm>