Cyber Hardened IBUC Console and SSHv2 Command Set
|
C-37
Engineered to Endure
TDT
Description: Display the input L-band power level.
Parameter:
<Level>
L-Band input power level [decimal number]
Table C.4
Default Values for the TAH, TAL, and TBT Commands
Power Level
TAH
Default Value
TAL
Default Value
TBT
Default Value
Watts
dBm
002
33.0
34.0
13.0
13.0
004
36.0
37.0
16.0
16.0
005
37.0
38.0
17.0
17.0
008
39.0
40.0
19.0
19.0
010
40.0
41.0
20.0
20.0
012
40.8
41.8
21.0
21.0
016
42.0
43.0
22.0
22.0
020
43.0
44.0
23.0
23.0
025
44.0
45.0
24.0
24.0
030
44.8
45.8
25.0
25.0
040
46.0
47.0
26.0
26.0
050
47.0
48.0
27.0
27.0
060
47.8
48.8
28.0
28.0
080
49.0
50.0
29.0
29.0
100
50.0
51.0
30.0
30.0
125
51.0
52.0
31.0
31.0
150
51.8
52.8
32.0
32.0
175
52.4
53.4
32.4
32.4
200
53.0
54.0
33.0
33.0
400
56.0
57.0
36.0
36.0
Q
Query: TDT
Response: Tx Input Power=<Level> dBm