Installation

Connectors

36

PRISM MPS Installation and Safety Instructions

Note:

The presets can be recalled through GPIO. See the PRISM MPS-MPD User 

Manual for details.

MPS-100/-200/-300 remote connector pin assignments and preset functions

Characteristic

Pin Function

Connector Pin 

Assignments

1 GND
2 Do not connect
3 Do not connect
4 Do not connect
5 Do not connect
6 GND
7 Do not connect
8 Do not connect
9 Do not connect
10 Preset 1 (In)
11 Preset 2 (In)
12 Preset 3 (In)
13 Preset 4 (In)
14 Preset 5 (In)
15 Preset 6 (In)

Summary of Contents for PRISM MPD

Page 1: ...PRISM MPS SDI IP Waveform Monitor Installation and Safety Instructions January 2022 P00010445B...

Page 2: ...like new performance All replaced parts modules and products become the property of Telestream In order to obtain service under this warranty Customer must notify Telestream of the defect before the e...

Page 3: ...MS ENCODED OR INCORPORATED WITHIN EQUIPMENT CONTACT THE NEAREST TELESTREAM SALES OFFICE DEFINITIONS Telestream meansTelestream LLC a Delaware limited liability company and its Affiliates or the local...

Page 4: ...has obtained a respective licensing right Customer shall pay when due all property taxes that may now or hereafter be imposed levied or assessed with respect to the possession or use of the Program or...

Page 5: ...HE PROGRAM EVEN IF TELESTREAM OR SUCH OTHERS HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES THIRD PARTY DISCLAIMER Except as expressly agreed otherwise third parties from whom Telestream may ha...

Page 6: ...ption 22 Where to Find More Information 23 Conventions Used in this Manual 24 Telestream Contact Information 24 Installation 26 Initial Product Inspection 26 Accessories 28 Operating requirements 29 E...

Page 7: ...n a particular installation Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own exp...

Page 8: ...lectrical Equipment for Measurement Control and Laboratory Use Part 1 General Requirements S curit CAN CSA C22 2 NO 61010 1 12 GI1 GI2 R2017 A1 Exigences de s curit pour l lectricit Mat riel de mesure...

Page 9: ...r Benutzer fur entsprechende Gegenmal3nahmen verantwortlich ist Attention Ceci est un produit de Classe A Dans un environnement domestique ce produit risque de creer des interferences radioelectriques...

Page 10: ...e for recycling please contact your local authority or where you purchased your product Battery Recycling This product may contain a rechargeable battery which must be recycled or disposed of properly...

Page 11: ...w the following safety precautions to avoid injury and prevent damage to this product or any products connected to it Carefully read all instructions Retain these instructions for future reference Com...

Page 12: ...all terminal ratings To avoid fire or shock hazard observe all rating and markings on the product Consult the product manual for further ratings information before making connections to the product Do...

Page 13: ...s Service safety summary and the General safety summary before performing any service procedures To avoid electric shock Do not touch exposed connections Do not service alone Do not perform internal s...

Page 14: ...afety codes For correct and safe operation of the product it is essential that you follow generally accepted safety procedures in addition to the safety precautions specified in this manual The produc...

Page 15: ...a tensione di rete siano contenute entro il 10 del valore nominale AVISO Para reduzir o risco de inc ndio e choque certifique se de que as flutua es da voltagem da rede el trica n o excedam 10 da faix...

Page 16: ...geeignete Strombegrenzungsvorrichtung z B eine Sicherung verf gt ATTENTION Le feu peut provoquer des d g ts et blesser des personnes Afin d viter tout risque de feu quand vous utiliser une alimentati...

Page 17: ...i n certificado que se suministr con el equipo VORSICHT Um die Gefahr von Feuer und Stromschlag zu verringern verwenden Sie das mit dem Ger t gelieferte zertifizierte Netzkabel AVERTIR Pour r duire le...

Page 18: ...ent data loss we strongly recommend you first shut down the instrument before disconnecting the power cord Press the power button or select Settings Utilities Power and then Power Down Now PRECAUCI N...

Page 19: ...SM monitor PRECAUCI N Para evitar posibles da os al monitor PRISM y los m dulos SFP se recomienda extraer los m dulos SFP antes de transportar el monitor PRISM VORSICHT Um eine m gliche Besch digung d...

Page 20: ...ichenden Zugang zu k hler Luft eingeschaltet wird AVERTIR La temp rature de l air ambient n est n cessairement celle l int rieure de l appareil Pour assurer un bon fonctionnement de ce dernier veuille...

Page 21: ...isopropil 75 convient Rincer l eau d min ralis e ensuite Avant d utiliser tout autre produit veuillez contact votre repr sentant Telestream ATTENZIONE Evitare l uso di detergenti chimici che potrebber...

Page 22: ...oms production studios OB vans and signal contribution distribution centers Features and Benefits of a Tool for IP SDI Infrastructures A comprehensive analysis and monitoring tool for a hybrid IP SDI...

Page 23: ...ith SMPTE 2022 6 7 and 2110 Stop display for monitoring video signals with a variety of transfer functions in a consistent manner Vector display equipped with a 3D LUT conversion allowing operators to...

Page 24: ...all it in a rack Provides basic safety and operating information included with kit MPS Portable Accessory Installation and Safety Manual User P00010447x Describes how to connect portable accessory equ...

Page 25: ...estream net See the Telestream Web site for your regional authorized Telestream distributor Telestream Technical Writers Email techwriter telestream net If you have comments or suggestions about impro...

Page 26: ...sit Prior to shipment the instrument is thoroughly inspected for mechanical defects The exterior should not have any scratches or impact marks Note Save the shipping carton and packaging materials for...

Page 27: ...ntrols and connectors Do not use abrasive compounds on any part of the instrument that may be damaged by it CAUTION Avoid the use of chemical cleaning agents that might damage the plastics used in the...

Page 28: ...ansceiver modules 10G Ethernet short range 850 nm transceiver module MP SFP Opt 10GESR 10G Ethernet long range 1310 nm transceiver module MP SFP Opt 10GELR 25G Ethernet short range 850 nm transceiver...

Page 29: ...ment must be within the range of temperatures listed in the Environmental Requirements table for safe operation or storage CAUTION Damage to the instrument can occur if this instrument is powered on a...

Page 30: ...is not necessarily inlet air temperature Damage to the instrument can occur if this equipment is powered on without sufficient access to cool air Altitude Operating To 3 000 meters 10 000 feet Maximu...

Page 31: ...back of the instrument any closer than the bends in the cables connected to the instrument Note Attaching the battery mount and battery to the back of the MPS does not significantly obstruct the air...

Page 32: ...ent Note A battery that can provide 12 amps continuous operation is required to power the product WARNING In the instrument only the line conductor is fused for over current protection The fuse is int...

Page 33: ...t shut down and restart This does not damage the instrument The instrument is not designed for a seamless transition between AC and DC power Equipment rack installation There is an optional accessorie...

Page 34: ...n to the selected audio channel pair 1 SDI1 SDI1 can operate in these modes Input only supporting SD HD 3G or 12G signals Quad Link 4K and 8K input when used in conjunction with SDI inputs 1 4 options...

Page 35: ...the instrument is locked to a PTP reference 3 3v drive TTL com patible AUX OUT SDI output of the selected SDI ST2022 or ST2110 input For Quad Link inputs 4K or 8K the AUX OUT is link 1 ST2110 20 30 i...

Page 36: ...or details MPS 100 200 300 remote connector pin assignments and preset functions Characteristic Pin Function Connector Pin Assignments 1 GND 2 Do not connect 3 Do not connect 4 Do not connect 5 Do not...

Page 37: ...power source DC In Connector for a standard XLR DC power source Pin 1 negative voltage Pin 2 not in use Pin 3 not in use Pin 4 positive voltage Ethernet port is a standard RJ 45 connector for 10 100...

Page 38: ...Output loop through of SDI1 input SDI4 SDI4 can operate in these modes Input only supporting SD HD 3G or 12G signals Quad Link 4K and 8K input when used in conjunction with SDI inputs 1 4 options MPD...

Page 39: ...UT Note This is a dual purpose pin that can be controlled in the UI to set to REF OUT or PPS REF OUT is a pass through of the REF IN PPS connector outputs a 1 PPS pulse per second signal when the inst...

Page 40: ...tallation Connectors 40 PRISM MPS Installation and Safety Instructions CAUTION To prevent possible damage to the PRISM monitor and SFP modules remove the SFP modules before transporting the PRISM moni...

Page 41: ...AC and DC power AC Operation Connect the power cord to the power connector on the rear panel of the instrument The power connector is keyed to be directional with the flat portion of the power cord h...

Page 42: ...al injury and property damage from falling instrument Batteries from different manufacturers vary in shape and weight When a battery is installed it can make the unit too heavy in the back and cause t...

Page 43: ...the instrument off CAUTION To prevent data loss we strongly recommend you first shut down the instrument before disconnecting the power cord Press the power button or select Settings Utilities Power...

Page 44: ...ns of numbered PRISM MPS Display Elements Item name Description Applications tabs Some applications have selectable tabs highlighted readouts you can use to display additional information Application...

Page 45: ...the available USB ports Use the USB port on the front of the optional rack accessory MPS RACK Power button Press the button to turn the instrument on or off To completely remove power from the instrum...

Page 46: ...banner to toggle the display between four tile and a full screen display of the selected application Swipe up or down or left or right as necessary to navigate menus and preset listings and to view a...

Page 47: ...ol bar Up to 8 applications can be listed on the application tool bar The number notes the location of the application on the application tool bar Click an application marked with a number to remove i...

Page 48: ...and then select Network and select the Web Remote tab The VNC client connects to the instrument in a separate window that appears exactly like the instrument display Web Browser To connect to the inst...

Page 49: ...to select Local Scaling and then click Apply 5 In the Control bar click the Connect icon to open the Connect menu 6 In the Connect menu enter the default password PRISM and then click Connect Note A u...

Page 50: ...rolled through API commands over the network or as an NMOS client Although API or NMOS operation does not allow you to fully interact with the instrument they are useful for making changes in a produc...

Reviews: