COMMAND OVERVIEW
167
Parameter
<NRf>
1 to 50 (item number)
Example
• If <NRf> is specified, only the numeric data for the
specified item is output.
:NUMERIC:NORMAL:VALUE? 1
-> 103.79E+00
• If <NRf> is omitted, the numeric data items from 1
to the number specified by the :
NUMeric[:NORMal]:NUMber command are output in
order.
:NUMERIC:NORMAL:VALUE?
->
103.79E+00,1.0143E+00,105.27E+00,..(omitted)..,50.0
01E+00
Numeric Data
Format
Measurement values U, I, P, PPPeak, PMPeak, S,
Q, LAMBda, CFU, CFI, FU, FI, UTHD and ITHD
Integrated values WH, WHP, WHM, AH, AHP and
AHM.
ASCII: <NR3> format. Example: [-]12.345E+00
Measurement values UPPeak, UMPeak, IPPeak
and IMPeak.
ASCII: <NR3> format. Example: [-]12.34E+00
Measurement values (PHI)
ASCII: <NR3> = 0~9.9 format. Example:[-]9.9E+00
ASCII: <NR3> = 10~99.9 format.
Example:[-]99.9E+00
ASCII: <NR3> = 100~999.9 format.
Example:[-]999.9E+000
Elapsed integration time (TIME)
ASCII: <NR1> format in units of seconds.
Example: 3600 for 1 hour (1:00:00).
FLOAT: IEEE single-precision floating point (4-
byte) format
No items (NONE)
ASCII: NAN (Not A Number)
FLOAT: 0x7E951BEE (9.91E+37)
Summary of Contents for Everywhereyoulook T3PM1100
Page 1: ...T3PM1100 Digital Power Meter User Manual ...
Page 191: ...COMMAND OVERVIEW 191 Example STATUS QMESSAGE ON STATUS QMESSAGE STATUS QMESSAGE 1 ...
Page 209: ...APPENDIX 209 Status system The diagram below is a description of the status system ...
Page 213: ...APPENDIX 213 Dimensions Units mm ...