COMMAND OVERVIEW
151
Example
:INPUT:CURRENT:CONFIG 20,10,1
:INPUT:CURRENT:CONFIG?
->:INPUT:CURRENT:CONFIG 20.0E+00,10.0E+00,
1.0E+00
[:INPut]:CURRent:POJump
Description
Sets or returns the jump destination range that is
used when a current peak over-range occurs.
Syntax
[:INPut]:CURRent:POJump {OFF|<Current>}
Query Syntax
[:INPut]:CURRent:POJump?
Parameter/
Return parameter
OFF
No jump destination current range.
<Current > See(:INPut:CURRent:RANGe).
Example
:INPUT:CURRENT:POJUMP 20A
:INPUT:CURRENT:POJUMP?
->:INPUT:CURRENT:POJUMP 20.0E+00
[:INPut]:CURRent:EXTSensor:CONFig<x>
Description
Sets or returns the valid external current sensor
range.
Syntax
[:INPut]:CURRent:EXTSensor:CONFig<x>
{ALL|<Voltage>[,Voltage]…}
Query Syntax
[:INPut]:CURRent:EXTSensor:CONFig<x>?
Parameter/
Return parameter
<x>
1,2(EXT1,EXT2), If <x> is omitted, by
default sets or returns EXT2 config.
ALL
All ranges are valid.
<Voltage> See(:INPut:CURRent:RANGe).