Functional Overview
WFM 601i Serial Component Monitor
2–13
SIGNAL PRESENT
525 LINES
10 BITS
DISPLAY
STATUS
FORMAT
RESET
FF CRC ERR SEC
STATUS
0
VALID
0
VALID
AP CRC ERR SEC
STATUS
F1 AP CRC VALUE
F2 AP CRC VA;UE
CHANGE SINCE RESET
FOC8
EA26
NO
0 DAY
10:12:25
ELAPSED TIME
Figure 2-6: Status screen with 525 line, 10-bit video.
When the serial receiver detects a no-signal condition, the STATUS screen
indicates SIGNAL MISSING. Under this condition the line rate and active bits
readouts are blanked. See figure 2-7.
In Figure 2-7 loss of signal condition is indicated. Note that the FF and AP EDH
status says “missing” because of the absence of the error status packet.
SIGNAL MISSING
DISPLAY
STATUS
FORMAT
RESET
FF CRC ERR SEC
STATUS
0
MISSING
5
MISSING
AP CRC ERR SEC
STATUS
F1 AP CRC VALUE
F2 AP CRC VA;UE
CHANGE SINCE RESET
FOC8
EA26
YES
0 DAY
10:12:25
ELAPSED TIME
Figure 2-7: Loss of signal condition is indicated.
Summary of Contents for WFM 601i
Page 4: ......
Page 12: ...Contents vi WFM 601i Serial Component Monitor...
Page 16: ...Preface x WFM 601i Serial Component Monitor...
Page 17: ...Getting Started...
Page 18: ......
Page 51: ...Operating Basics...
Page 52: ......
Page 58: ...At A Glance 2 6 WFM 601i Serial Component Monitor...
Page 76: ...Functional Overview 2 24 WFM 601i Serial Component Monitor...
Page 77: ...Reference...
Page 78: ......
Page 104: ...Measurement Theory 3 26 WFM 601i Serial Component Monitor...
Page 105: ...Appendices...
Page 106: ......
Page 118: ...Appendix B Multipin Connectors B 4 WFM601i Serial Component Monitor...
Page 123: ...Glossary...
Page 124: ......
Page 129: ...Index...
Page 130: ......
Page 134: ......
Page 135: ......