Command Descriptions
TDS3000, TDS3000B, and TDS3000C Series Programmer Manual
2- 279
TRIGger:A:PULse:RUNT? (Query Only)
Returns the runt pulse trigger settings.
Trigger
TRIGger:A:PULse:RUNT?
TRIGGER:A:PULSE:RUNT?
might return
:TRIGGER:A:PULSE:RUNT:THRESHOLD:HIGH 2.8000000000;LOW
0.7000000000;:TRIGGER:A:PULSE:RUNT:WHEN LESSTHAN;WIDTH
0.0000011880
.
TRIGger:A:PULse:RUNT:POLarity
Sets or returns the runt-pulse logic trigger signal polarity value.
Trigger
TRIGger:A:RUNT:PULse:POLarity { EITher | POSITIVe | NEGAtive }
TRIGger:A:RUNT:PULse:POLarity?
EITher
sets the oscilloscope to trigger on either
POSITIVe
or
NEGAtive
polarity
runt signals.
POSITIVe
sets the oscilloscope to trigger only on positive-polarity runt pulses.
NEGAtive
sets the oscilloscope to trigger only on negative-polarity runt pulses.
TRIGGER:A:PULSE:POLARITY NEGATIVE
specifies that the oscilloscope only trigger on negative-polarity runt pulses.
TRIGger:A:PULse:RUNT:THReshold? (Query Only)
Returns the runt pulse trigger upper and lower threshold voltage values.
Trigger
TRIGger:A:PULse:RUNT:THReshold?
Group
Syntax
Examples
Group
Syntax
Arguments
Examples
Group
Syntax
Summary of Contents for TDS3000 Series
Page 8: ...Table of Contents vi TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...
Page 10: ...Preface viii TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...
Page 38: ...Getting Started 1 28 TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...
Page 82: ...Command Groups 2 44 TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...
Page 388: ...Status and Events 3 20 TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...