![Tektronix TDS3000 Series Program Manual Download Page 25](http://html.mh-extra.com/html/tektronix/tds3000-series/tds3000-series_program-manual_1079160025.webp)
Getting Started
TDS3000, TDS3000B, and TDS3000C Series Programmer Manual
1- 15
H
The
Back Space
button deletes the character to the left of the cursor
position in the field.
H
The
Delete
button deletes the character at the cursor position in the field.
H
The
Clear
button deletes all characters from the current field.
9.
Push the
OK Accept
side button to apply the field settings. Push the
MENU
OFF
button to exit from the menu without applying any changes.
10.
Push the
Test Connection
side menu button to verify that the Ethernet
settings are correct and that the oscilloscope can locate itself on the network.
11.
If the oscilloscope does not establish a connection to the network, check that
you correctly entered the Ethernet instrument settings, and that you have
connected the oscilloscope to the Ethernet connector with an appropriate
10baseT cable. If the settings and cable are correct, contact your network
administrator for help.
Ethernet Printer Settings.
This procedure presumes that you have successfully
established communications with the network by using one of the previous
procedures.
Do these steps to add a network printer to the oscilloscope (you can store up to
21 printers in the Ethernet network printer list):
1.
Obtain the printer name, server name, and server IP address of the network
printer or printers to which you are sending hard copy data.
2.
Power on the oscilloscope.
3.
Push the
UTILITY
menu button.
4.
Push the
System
screen button and select the
I/O
System.
5.
Push the
Ethernet Printer Settings
screen button. The oscilloscope displays
the Printer Configuration window, as shown in Figure 1--10.
6.
Push the
Add Printer
screen button to display the Add Printer dialog box.
7.
Push the side menu
↑
and
↓
buttons to select a field to edit.
8.
Enter the required information into each field:
H
The general purpose knob selects a character in the character list. The list
of available characters changes depending on which field is selected.
H
The
Enter Character
button enters the selected character from the
character list. You can also use the
SELECT
button next to the general
purpose knob to enter the selected character.
H
The
←
and
→
buttons move the cursor left or right in the current field.
Summary of Contents for TDS3000 Series
Page 8: ...Table of Contents vi TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...
Page 10: ...Preface viii TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...
Page 38: ...Getting Started 1 28 TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...
Page 82: ...Command Groups 2 44 TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...
Page 388: ...Status and Events 3 20 TDS3000 TDS3000B and TDS3000C Series Programmer Manual ...